Windsor 22 Vacuum Cleaner User Manual


 
English 11
Emergency stop button is unlocked
(when the main cable is inserted):
the charging process is started
the battery indicator lamp is yellow and
flashing
Î Add distilled water one hour before the
end of the charging process; follow the
correct acid level. There are correspon-
ding indicators on the battery.
ƽ Danger
Danger of caustic material!
Adding water to the battery in its dischar-
ged state can cause the acid to leak.
Use safety glasses while handling batte-
ry acid and follow the safety instructions
to avoid personal injury or damage to
clothes.
Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
Warning
Risk of damage!
Use only distilled or desalinated water
(VDE 0510) for filling the battery.
Do not add any substances (so-called
performance improving agents), this will
void the warranty.
Warning
Only use maintenance-free batteries while
replacing batteries in package appliances.
Î If the emergency stop button is pressed,
turn the key switch to position 0 and re-
lease the emergency stop button by
turning.
Î Turn the main switch to "1".
Warning!
Risk of damage. Raise the squeegee tool
before reversing.
Note
To put the brush drive out of operation im-
mediately release the control handle.
Warning
Risk of damage. Only use the recommended
detergents. With respect to different deter-
gents the operator bears the increased risk
regarding the operational safety and danger
of accident. Only use detergents that are
free from solvents, hydrochloric acid and hy-
drofluoric acid.
Note
Do not use highly foaming detergents. Ob-
serve the meter mixing notes.
Detergent is added to the fresh water on the
way to the cleaning head with the help of a
dosaging device.
Note
1% detergent gets added via the metering
equipment. The metering can be set bet-
ween 0 and 3%. For higher metering, you
can add the entire quantity of detergent to
the fresh water tank.
The metering equipment has been designed
for 2.5 litre (0.66 gal) detergent bottles.
Warning
Risk of blocking on account of drying deter-
gent. The flow meter of the metering equip-
ment can stick on account of drying
detergent and hamper the functioning of the
Maintenance-free batteries (wet batte-
ries)
Recommended batteries
Order No. Description
6.654-093.0 75 Ah, maintenance-free, 2
pieces required
6.654-097.0 80 Ah, maintenance-free, 2
pieces required
Start up
Operation
Chemical filling