MAINTENANCE-PERIODIC
86292100 CLIPPER DUO 10/02/07
4-3
PERIODIC MAINTENANCE
Twice a month, flush a white vinegar solution (One
quart vinegar to two gallons of water) or anti-
browning solution (mixed as directed) through the
extractor. This will prevent build-up of alkaline
residue in the system. If spray jets become clogged,
remove the spray tips, wash them thoroughly, and
blow-dry.
NOTE: Do not use pins, wire, etc. to clean
nozzles as this could destroy spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked
hoses should be repaired or replaced to eliminate
vacuum or solution pressure loss. If the cable
insulation is broken or frayed, repair or replace it
immediately. Don’t take chances with electrical fire
or shock.
DAILY / REGULAR MAINTENANCE
NOTE: Before making any adjustments or repairs
to the machine, disconnect the power cord from
electrical source.
1. Empty unused cleaning solution from the
solution tank.
2. Flush pumping system with 4 or 7 liters of clean,
hot water.
3. After each use, rinse tank with fresh water.
Periodically inspect the recovery tank and
decontaminate if necessary, using a Hospital
Grade Virucide or a 1-10 bleach to water
solution. Waste water should be disposed of
properly.
4. Check for and remove any lint or debris around
vac shoe.
5. Check spray jets for full spray pattern.
6. Remove lint and dirt build-up from brush and
housing.
7. Check float and shut-off screen and clean as
necessary.