Operating Your Furnace
BUILT-IN THERMOSTAT MODELS 1403611, 1403612,
2203611, 2203612, 3003611 and 3003612
Refer to this sheet and sheet 16 (or) 17 for "Safety,
Operating Instructions" and "Turn Gas Off ToAppliance."
These furnaces are equipped with a manually operated
piezo spark ignition device to ignite the pilot gas. Follow
the steps under "Operating Instructions" and use the
manual spark ignitor (shown in Fig. 13) to light the pilot
in place of a match. Press spark ignitor button repeatedly.
WALL THERMOSTAT MODELS 1403622, 1403621,
2203622, 2203621, 3003622 and 3003621
Refer to this sheet and sheet 18 (or) 19 for "Safety,
Operating Instructions" and "Turn Gas Off ToAppliance."
These furnaces are equipped with a manually operated
piezo spark ignition device to ignite the pilot gas. Follow
the steps under "Operating Instructions" and use the
manual spark ignitor (shown in Fig. 13) to light the pilot
in place of a match. Press spark ignitor button repeatedly.
WARNING
THE SURFACE OF THE FURNACE IS HOT DUR-
ING OPERATION. KEEP CHILDREN, CLOTHING,
FURNITURE, AND FLAMMABLE MATERIAL AWAY
FROM IT.
WARNING
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPORS NEAR THE
FURNACE.
LIGHTING THE FURNACE WITH A MATCH
If the spark ignitor fails to provide spark to light the pilot,
loosen the wing nut holding the peep hole cover. This will
open the peep hole into the heat exchanger and the pilot
can be ignited with a match.
1. Follow the instructions under "LIGHTING AND
OPERATING INSTRUCTIONS" and use a match to
light the pilot as instructed.
WARNING
DANGER OF IGNITION FLASH
AND EYE INJURY OR BLINDNESS
PROTECT YOUR EYES. NEVER ATTEMPT TO
LIGHT PILOT WITH GAS CONTROL VALVE
KNOB IN "ON" POSITION. FLASHBACK COULD
OCCUR.
2. After lighting the pilot, carefully replace the pilot
observation door (peep hole cover) and tighten wing
nut down.
On new installations the gas lineswill be filled withair and
it may take several tries to establish the pilot flame.
Check the manual shut-off valve in the gas line. It must
be in the open position (handle parallel to gas line) before
you can light your furnace.
Your furnace is equipped with a 100% safety pilot which
will shut off the gas valve in case the pilot is not burning
or functioning properly. Make sure the pilot is adjusted pro-
perly and that the thermocouple or generator connection
at the control valve is tight. If furnace will not stay lit, call
your local gas utility company.
Your furnace is equipped with a built-in pressure regulator.
L.R Gas models also have a regulator at the supply tank.
If you have a question regarding the amount of fuel
consumed, call your local gas utility or gas supplier. DO
NOT TAMPER WITH THE REGULATORS OR BURNER
ORIFICES, AS PROBLEMS RESULTING THEREFROM
MAY CAUSE PRODUCT FAILURE NOT COVERED BY
WARRANTY. Input and Output shown on the Rating Plate,
located in burner compartment, must not be exceeded.
IMPORTANT
KEEP BURNER AND CONTROL COMPARTMENT
CLEAN.
THERMOSTAT (TYPICAL)
SQUEEZE RRMLY
9011"1 SIDES
AND UFI" TO
REMOVE COVER
WARNING
DANGER OF BODILY INJURY OR DEATH
DO NOT OPERATE THE FURNACE WITH A
BROKEN OR MISSING PILOT OBSERVATION
DOOR.