13
setting is 76°F, the lowest cool setting can-
not be below 77°F (see diagram below).
• TWO HOUR TEMPERATURE OVER-
RIDE — Press or until the
display shows the temperature you want.
The thermostat will override current pro-
gramming and keep the room temperature
at the selected temperature for two hours.
After two hours, the thermostat will auto-
matically revert to the program.
• HOLD TEMPERATURE — The thermostat
can hold any temperature within its range
for an indefinite period, without reverting to
the program. Press
HOLD
COPY
. HOLD will be
displayed. Then choose the desired hold
temperature by pressing or .
The thermostat will hold the room tempera-
ture at the selected setting until you press
RUN
PRGM
to start program operation again. This
feature is ideal for energy conservation
when the building is unoccupied for an
extended period of time.
• °F/°C CONVERTIBILITY — Press
TIME
FWD
and
TIME
BACK
at the same time until the temperature
display is in °C (Celsius). To display °F,
repeat the process.
79
78
77
76
75
74
COOLING TEMPERATURES
HEATING TEMPERATURES
DEAD BAND 1°F