INSTALLER/CONFIGURATION MENU
Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press
or to change a menu item options.
INSTALLER/CONFIGURATION MENU
MENU
REF.
HP SS PRESS
BUTTON
DISPLAYED
(FACTORY DE-
FAULT)
Press
or to
select from listed op-
tions
COMMENTS
1 1 1 MENU (MS 2) HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor),
Heat Pump 2 (HP 2, 2 compressor or 2
speed compressor), or Single Stage (SS 1)
2 2 2 MENU (GAS) for SS or MS ELE GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3 3 3 MENU CS (3) 0, 1, 2, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 disables feature
4 4 4 MENU E (On) OFF Selects Energy Management Recovery (EMR)
On or OFF.
5 5 MENU CR Heat (ME) SL, FA Adjustable Anticipation:
Selects heating cycle rate for MS or SS in #1 only
6 5 MENU CR Heat Pump
(ME)
SL, FA Adjustable Compressor Anticipation
(Heat Pump) [only when heat pump (Heat/Cool)
selected in #1]
7 6 6 MENU CR Cool (ME)
or
CR Au (FA)
SL, FA
SL
Adjustable Anticipation:
Selects the cycle rate for cooling (only when
MS 2 or SS 1 is selected in item 1.) or
Selects the cycle rate for Emergency mode
and Auxiliary stage if Heat Pump is selected
in item 1.
8 7 7 MENU CL (OFF) CL On Compressor Lockout Time
9 8 8 MENU Cool Off, Em Heat
Auto
Heat Auto Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Confi guration
with Automatic Changeover capability
10 9 9 MENU dL (On) dL OFF Selects Display Light On or OFF
11 10 10 MENU 0
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12 11 11 MENU °F °C Selects Fahrenheit/Celsius Temperature Display
13 12 12 MENU (On) b OFF May select Beeper OFF to stop audible
key feedback
14 13 13 MENU P (7) 3, 0 Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models.
15 14 14 MENU PS (2) 4 Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
16 15 15 MENU Heat AS (On) OFF Automatic Schedule for heat mode
17 16 16 MENU Cool AS (On) OFF Automatic Schedule for cool mode
18 17 MENU Heat FA (On) OFF Fast Heat option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
19 18 MENU Cool FA (On) OFF Fast Cool option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
20 19 17 MENU Remote (OFF) On Selects Remote Sensor On/OFF
MENU Remote
(In)
Outdoor Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
MENU Indoor Loc
(On)
OFF Selects Local Sensor (in thermostat) to OFF.
N/A if Remote is selected to Outdoor