White Rodgers 1F94-71 Thermostat User Manual


 
14
TWO HOUR TEMPERATURE OVER-
RIDE — Press or until the
display shows the temperature you want.
The thermostat will override current pro-
gramming and keep the room temperature
at the selected temperature for two hours.
After two hours, the thermostat will auto-
matically revert to the program.
HOLD TEMPERATURE — The thermostat
can hold any temperature within its range
for an indefinite period, without reverting to
the program. Press
HOLD
COPY
. HOLD will be
displayed. Then choose the desired hold
temperature by pressing or .
The thermostat will hold the room tempera-
ture at the selected setting until you press
RUN
PRGM
to start program operation again. This
feature is ideal for energy conservation when
the building is unoccupied for an extended
period of time.
°F/°C CONVERTIBILITY — Press
TIME
FWD
and
TIME
BACK
at the same time until the temperature
display is in °C (Celsius). To display °F,
repeat the process.
ADJUSTABLE HEATING AND COOLING
CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.
A cooling anticipation setting of less
than 10 may cause decreased compres-
sor life.
CAUTION
!