White Rodgers 1F85RF-275 Thermostat User Manual


 
6
PressPress
PressPress
Press
DisplayedDisplayed
DisplayedDisplayed
Displayed
Press Press
Press Press
Press
or or
or or
or
StepStep
StepStep
Step
Button(s)Button(s)
Button(s)Button(s)
Button(s)
(Factory Default)(Factory Default)
(Factory Default)(Factory Default)
(Factory Default)
to selectto select
to selectto select
to select
CommentsComments
CommentsComments
Comments
1
SystemSystem
SystemSystem
System
MS2MS2
MS2MS2
MS2
SS1, HP2, HP1SS1, HP2, HP1
SS1, HP2, HP1SS1, HP2, HP1
SS1, HP2, HP1 Selects Single stage, Multi-stage, or Heat Pump
(Single stage or 2-stage) system configuration
2
SystemSystem
SystemSystem
System
LER (OFF)LER (OFF)
LER (OFF)LER (OFF)
LER (OFF)
LER (ON)LER (ON)
LER (ON)LER (ON)
LER (ON) Selects learn mode OFF or ON
3
SystemSystem
SystemSystem
System
OUTSIDE OUTSIDE
OUTSIDE OUTSIDE
OUTSIDE
(OFF)(OFF)
(OFF)(OFF)
(OFF)
OUTSIDE OUTSIDE
OUTSIDE OUTSIDE
OUTSIDE
(ON)(ON)
(ON)(ON)
(ON) Selects OUTSIDE sensor OFF or ON
4
SystemSystem
SystemSystem
System
REMOTE REMOTE
REMOTE REMOTE
REMOTE
(OFF)(OFF)
(OFF)(OFF)
(OFF)
REMOTE REMOTE
REMOTE REMOTE
REMOTE
(ON)(ON)
(ON)(ON)
(ON) Selects REMOTE (indoor) sensor OFF or ON
5
SystemSystem
SystemSystem
System
LOCAL LOCAL
LOCAL LOCAL
LOCAL
(ON)(ON)
(ON)(ON)
(ON)
LOCAL LOCAL
LOCAL LOCAL
LOCAL
(OFF)(OFF)
(OFF)(OFF)
(OFF) Selects LOCAL sensor ON or OFF
6
SystemSystem
SystemSystem
System
CH CH
CH CH
CH
(0)(0)
(0)(0)
(0)
1 to 91 to 9
1 to 91 to 9
1 to 9 Select Receiver frequency offset
7
SystemSystem
SystemSystem
System
PRG 4PRG 4
PRG 4PRG 4
PRG 4
PRG 0, PRG 2PRG 0, PRG 2
PRG 0, PRG 2PRG 0, PRG 2
PRG 0, PRG 2 Selects Programmable Periods
8
SystemSystem
SystemSystem
System
EMR EMR
EMR EMR
EMR
(ON)(ON)
(ON)(ON)
(ON)
EMR EMR
EMR EMR
EMR
(OFF)(OFF)
(OFF)(OFF)
(OFF) Selects Energy Management Recovery OFF or ON
9
SystemSystem
SystemSystem
System
CR HEAT COOL CR HEAT COOL
CR HEAT COOL CR HEAT COOL
CR HEAT COOL
(FA)(FA)
(FA)(FA)
(FA)
SLSL
SLSL
SL Selects Fast or Slow cycle selection
10
SystemSystem
SystemSystem
System
CL CL
CL CL
CL
(OFF)(OFF)
(OFF)(OFF)
(OFF)
CL CL
CL CL
CL
(ON)(ON)
(ON)(ON)
(ON) Selects Compressor Lockout CL OFF or ON
11
SystemSystem
SystemSystem
System
CdL CdL
CdL CdL
CdL
(ON)(ON)
(ON)(ON)
(ON)
CdL CdL
CdL CdL
CdL
(OFF)(OFF)
(OFF)(OFF)
(OFF) Selects Backlight Display ON or OFF
12
SystemSystem
SystemSystem
System
FA HEAT COOL FA HEAT COOL
FA HEAT COOL FA HEAT COOL
FA HEAT COOL
(ON)(ON)
(ON)(ON)
(ON)
FA HEAT COOL FA HEAT COOL
FA HEAT COOL FA HEAT COOL
FA HEAT COOL
(OFF)(OFF)
(OFF)(OFF)
(OFF) Selects Fast Second Stage ON or OFF
13
SystemSystem
SystemSystem
System
0 FLTR0 FLTR
0 FLTR0 FLTR
0 FLTR
0–19500–1950
0–19500–1950
0–1950
(increments of 50)(increments of 50)
(increments of 50)(increments of 50)
(increments of 50) Selects filter replacement run time.0 =Disabled
14
SystemSystem
SystemSystem
System
0 F0 F
0 F0 F
0 F
4 LO to 4 HI4 LO to 4 HI
4 LO to 4 HI4 LO to 4 HI
4 LO to 4 HI Selects Temperature Display Adjustment 4 LO 4 HI
(Room Temperature)(Room Temperature)
(Room Temperature)(Room Temperature)
(Room Temperature)
15
SystemSystem
SystemSystem
System
4:00 HOLD4:00 HOLD
4:00 HOLD4:00 HOLD
4:00 HOLD
0:00 to 8:000:00 to 8:00
0:00 to 8:000:00 to 8:00
0:00 to 8:00 Selects Temporary Program Override Time
(Increments of 15 minutes)(Increments of 15 minutes)
(Increments of 15 minutes)(Increments of 15 minutes)
(Increments of 15 minutes) 0:00 =Disabled
16
SystemSystem
SystemSystem
System
FF
FF
F
CC
CC
C For C selection
Selects temperature display as F° or C°
17
SystemSystem
SystemSystem
System
LR HEAT LR HEAT
LR HEAT LR HEAT
LR HEAT
(90)(90)
(90)(90)
(90)
LR 62 to LR 89LR 62 to LR 89
LR 62 to LR 89LR 62 to LR 89
LR 62 to LR 89 Selects Limited HEAT range
18
SystemSystem
SystemSystem
System
LR COOL LR COOL
LR COOL LR COOL
LR COOL
(45)(45)
(45)(45)
(45)
LR 46 to LR 82LR 46 to LR 82
LR 46 to LR 82LR 46 to LR 82
LR 46 to LR 82 Selects Limited COOL range
19
SystemSystem
SystemSystem
System
CA CA
CA CA
CA
(OFF)(OFF)
(OFF)(OFF)
(OFF)
CA CA
CA CA
CA
(ON)(ON)
(ON)(ON)
(ON) Selects Comfort Alert Lock
20
SystemSystem
SystemSystem
System
OFF LOCKOFF LOCK
OFF LOCKOFF LOCK
OFF LOCK
ON LOCKON LOCK
ON LOCKON LOCK
ON LOCK Selects Buttonpad Lockout
21
0 00 LOCK0 00 LOCK
0 00 LOCK0 00 LOCK
0 00 LOCK
001 to 999001 to 999
001 to 999001 to 999
001 to 999 Selects Buttonpad lockout combination number
Press System to set code
RunRun
RunRun
Run Returns to the OFF mode
The configuration menu allows you to set certain thermostat
operating characteristics to your system or personal require-
ments.
Set SYSTEM button to
OFFOFF
OFFOFF
OFF, then simultaneously press
and to enter configuration menu. The display will
show the first item in the configuration menu.
The configuration menu table summarizes the configuration
options. An explanation of each option follows.
Press SYSTEM to change to the next menu item. To exit the
menu and return to the program operation, press RUN. If no
keys are pressed within fifteen minutes, the thermostat will
revert to normal operation.
1)
Single Stage, Multi-stage or Heat Pump ConfigurationSingle Stage, Multi-stage or Heat Pump Configuration
Single Stage, Multi-stage or Heat Pump ConfigurationSingle Stage, Multi-stage or Heat Pump Configuration
Single Stage, Multi-stage or Heat Pump Configuration
This menu item requires you configure the thermostat to
match your system. Choose your system option from the
table below:
System TypeSystem Type
System TypeSystem Type
System Type
Select OptionSelect Option
Select OptionSelect Option
Select Option
Single Stage Heat/Cool systems SS1
Multi-Stage Heat/Cool systems (No Heat Pump) MS2
Heat Pump system, 1 compressor or 1 speed compressor HP1
Heat Pump systems, 2 compressors or 2 speed compressor HP2
The thermostat is factory defaulted to MS2. To select a
different option, press the or key to scroll through
the choices.
THERMOSTTHERMOST
THERMOSTTHERMOST
THERMOST
AA
AA
A
T CONFIGURAT CONFIGURA
T CONFIGURAT CONFIGURA
T CONFIGURA
TION MENUTION MENU
TION MENUTION MENU
TION MENU
2)
Select Learn Mode On or OffSelect Learn Mode On or Off
Select Learn Mode On or OffSelect Learn Mode On or Off
Select Learn Mode On or Off – Selecting
LER OnLER On
LER OnLER On
LER On
enables the learn mode of the thermostat receiver. Your
thermostat is configured at the factory to recognize the
remote sensor shipped with it. The Learn Mode Option is
used only when required as described in
Learn ModeLearn Mode
Learn ModeLearn Mode
Learn Mode
OptionOption
OptionOption
Option.
3)
Selects OUTSIDE sensor OFF or ONSelects OUTSIDE sensor OFF or ON
Selects OUTSIDE sensor OFF or ONSelects OUTSIDE sensor OFF or ON
Selects OUTSIDE sensor OFF or ON – Selecting
OUTSIDE ON enables the thermostat to read a wireless
outdoor temperature sensor that has been configured for
Sensor O in the Learn Mode. This allows the thermostat
to display the outdoor temperature reading.
4)
Selects REMOTE sensor OFF or ON Selects REMOTE sensor OFF or ON
Selects REMOTE sensor OFF or ON Selects REMOTE sensor OFF or ON
Selects REMOTE sensor OFF or ON – Selecting
REMOTE ON allows the thermostat to sense an indoor
remote sensor that has been set-up the Learn mode. The
maximum number of Indoor Remote Sensors is 1
configured to sensor A, B or C.
5)
Selects LOCAL sensor ON or OFF Selects LOCAL sensor ON or OFF
Selects LOCAL sensor ON or OFF Selects LOCAL sensor ON or OFF
Selects LOCAL sensor ON or OFF – Selecting LOCAL
ON allows the thermostat to use the onboard temperature
sensor exclusively or for averaging with the remote
sensor readings. To control temperature using only the
indoor remote sensor temperature(s), use the
or
buttons to select
LOCAL OFFLOCAL OFF
LOCAL OFFLOCAL OFF
LOCAL OFF.
6)
Select Receiver frequency offsetSelect Receiver frequency offset
Select Receiver frequency offsetSelect Receiver frequency offset
Select Receiver frequency offset – This option allows
you to select a different channel than the factory default
for communication between the thermostat and remote
sensor. Note: If a different channel is selected on the
thermostat it must also be changed to the same
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENU
Press the System button until
OFF OFF
OFF OFF
OFF is displayed, then press the and simultaneously