White Rodgers 1F82-0261 Thermostat User Manual


 
7
Do not allow the compressor to run unless the
compressor oil heaters have been operational for 6
hours and the system has not been operational for at
least 5 minutes.
CAUTION
!
MANUAL OPERATION
HOLD TEMPERATURE — With the SYSTEM switch set
to HEAT or COOL, momentarily press RUN/HOLD button.
HOLD will be displayed. Use or to adjust the
temperature. The thermostat will hold the room temperature
at the selected setting until you press RUN/HOLD button to
start program operation again.
TEMPERATURE OVERRIDE (TEMPORARY HOLD)
— Press or until the temperature you want is
displayed. The thermostat will override current programming
and keep the room temperature at the selected temperature
for 2 hours or until the next program period begins. Then
the thermostat will automatically revert to the program.
PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostat’s program to
meet your needs. For maximum comfort and effi ciency, keep
the following guidelines in mind when planning your program.
When heating (cooling) your building, program the
temperatures to be cooler (warmer) when the building is
vacant or during periods of low activity.
During early morning hours, the need for cooling is usually
minimal.
Planning Your Program
Look at the factory preprogrammed times and temperatures
shown in the sample schedule. If this program will suit your
needs, simply press the RUN/HOLD button to begin running
the factory preset program.
PROGRAMMING
If you want to change the preprogrammed times and
temperatures, follow these steps.
Determine the time periods and temperatures for your program.
You must program four periods for each day. However, you
may use the same heating and cooling temperatures for
consecutive time periods. You can choose start times, heating
temperatures, and cooling temperatures independently (for
example, you may select 5:00 AM and 70° as the weekday 1st
period heating start time and temperature, and also choose
7:00 AM and 76° as the weekday 1st period cooling start
time and temperature).
Use the table to plan your program time periods and the
temperatures you want during each period. Fill in the complete
table to have a record of your programs.
Entering Your Program
Set Current Time and Day
1. Press TIME button once. The display will show the hour
only.
EXAMPLE:
2. Press and hold either
or until you reach the correct
hour and AM/PM designation (AM begins at midnight; PM
begins at noon).
3. Press TIME once again. The display window will show the
minutes only.
EXAMPLE:
4. Press and hold either or until you reach the correct
minutes.
5. Press TIME once again. The display will show the day of
the week.
6. Press or until you reach the current day of the
week.
7. Press RUN/HOLD once. The display will show the correct
time, day, room temperature and set-point temperature.
WEEKDAYS
(5 Day)
SATURDAY
(1 Day)
Start
Time Temp
Start
Time Temp
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
SAMPLE
Heating/Cooling Schedule Plan (Factory Program)
Period
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
70°F
62°F
70°F
62°F
78°F
85°F
78°F
82°F
SUNDAY
(1 Day)
Start
Time Temp
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
70°F
62°F
70°F
62°F
78°F
85°F
78°F
82°F
70°F
62°F
70°F
62°F
78°F
85°F
78°F
82°F
HEAT
COOL
WEEKDAYS
(5 Day)
SATURDAY
(1 Day)
Start
Time Temp
Start
Time Temp
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
Heating/Cooling Schedule Plan
Period
SUNDAY
(1 Day)
Start
Time Temp
HEAT
COOL