Install burner (also refer to instructions packed with burner):
Burners designed for use with Weil-McLain 68 boilers must not be used on GOLD Oil
boilers. Contact individual burner manufacturers for GOLD Oil applications.
Install Non-Packaged Boiler
CONTINUED
Water Boiler Controls
FIGURE 4
Water
Pressure
Gauge
Tankless
Heater
Control
Circulator
Limit
Control
Drain
Valve
For A-SGO-W boiler:
1. Secure universal mounting flange and gasket to
burner mounting door. Use three bolts provided.
2. Secure burner on flange with three bolts.
3. Position burner so end of air tube is level to
1½° tilt downward. Open door to verify burner
position. End of air tube should be flush to ¼"
recessed from inside wall of burner door
refractory. Check for secure placement of
insulation on target wall, chamber floor and
burner mounting door. Securely close door.
9