Check boiler area
To prevent potential of severe personal injury, death or substantial property
damage, eliminate all materials discussed below from the boiler vicinity. If
contaminants are found:
Remove products immediately from the area. If they have been there for an
extended period, call a qualified service technician to inspect the boiler and
vent system for possible damage from acid corrosion.
If products cannot be removed, immediately call a qualified service technician
to install an outside combustion air source for the boiler (if not already
installed).
1. Combustible/flammable materials Do not store combustible materials, gasoline or any
other flammable vapors or liquids near the boiler. Remove immediately if found.
2. Air contaminants Products containing chlorine or fluorine, if allowed to contaminate the
boiler intake air, will cause acidic condensate in the vent and boiler. This will cause significant
damage to the vent and/or boiler if allowed to continue. Read the list of potential materials
listed on page 4 of this manual. If any of these products are in the room from which the boiler
takes its combustion air, they must be removed immediately or the boiler combustion air
must be supplied from outside. See WARNING above.
Check air openings
1. Verify that combustion and ventilation air openings to the boiler room and/or building are
open and unobstructed.
2. Verify that boiler vent discharge and air intake are clean and free of obstructions. Remove any
debris on the air intake or flue exhaust openings.
Check boiler pressure/temperature gauge
1. Make sure the pressure reading on the boiler pressure/temperature gauge does not exceed 24
psig. Higher pressure may indicate a problem with the expansion tank.
Contact a qualified service technician if problem persists.
Boiler must be serviced and
maintained
User maintenance procedures
The boiler should be inspected and started annually, at
the beginning of the heating season, only by a qualified
service technician. In addition, the maintenance and care
of the boiler designated on page 5 and explained on the
following pages must be performed to assure maximum
boiler efficiency and reliability. Failure to service and
maintain the boiler and system could result in equipment
failure, causing possible severe personal injury, death or
substantial property damage.
The following information provides detailed instructions
for completing the maintenance items listed in the
maintenance schedule, page 5. In addition to this
maintenance, the boiler must be serviced and started up
at the beginning of each heating season by a qualified
service technician.
—— DAILY ——