Part number 550-141-812/0699 5
GOLD GV SerGOLD GV Ser
GOLD GV SerGOLD GV Ser
GOLD GV Ser
. 3 — . 3 —
. 3 — . 3 —
. 3 —
UserUser
UserUser
User
’s’s
’s’s
’s
information manual information manual
information manual information manual
information manual
Service technician
(see following pages for instructions)
Owner maintenance
(see following pages for instructions)
ANNNUAL START-UP
Inspect:
• Any problems reported by owner
• Boiler area
• Air openings
• Flue gas vent
• Boiler heating surfaces
• Water piping
• Condensate drain system
Service:
• Lubricate blower motor
• Lubricate any circulators requiring oil
Start-up:
• Perform start-up per manual
Check/test:
• Check gas piping for leaks
• Check cold fill & operating pressures
• Check temperature mixing system
• Check/maintain components - vents,
limits, expansion tank, gauges, igniter
• Inspect & operate relief valve
Review:
• Review maintenance procedures with
owner
Daily
• Check boiler area
• Check air openings
• Check pressure gauge
Monthly
• Check boiler interior piping
• Check venting system
• Check air vents
• Check condensate drain system
• Check relief valve
Periodically
• Test low water cutoff (if used)
• Clean vent termination/air intake
screens
Every 6 months
• Oil blower motor
• Operate relief valve
End of season • Shut down procedure
Perform maintenance per schedule below