Weber 42377 Burner User Manual


 
8
GAS INSTRUCTIONS

TOSIDE
BURNER
TOREGULATOR
TOPVIEW

Check:
1) Corrugated gas line-to-Accessory “T” Connection.
2) Main gas Supply to regulator
ƽWARNING: If there is a leak a connection(1),
retighten the fi tting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after retightening the fi tting, turn OFF
the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your region using
the contact information sheet provided with your
manual.
Check:
When leak checks are complete, turn gas supply OFF at
the source and rinse connections with water.
Side Burner Lighting Instructions
ƽ DANGER
Failure to open the lid while igniting the side
burner, or not waiting 5 minutes to allow the
gas to clear if the side burner does not light,
may result in an explosive fl ame-up which
can cause serious bodily injury or death.
Lighting the side burner.
1) Open the side burner lid.
2) Check that the side burner valve is turned OFF. (Push
the knob down and turn clockwise to ensure it is in the
off position.).
3) Turn the gas supply valve on.
4) Push down and turn the side burner control valve to
START/HI.
5) Push igniter button and hold until burner ignites. You
will hear the igniter sparking.
ƽ CAUTION: Side burner fl ame may be diffi cult to see
on a bright sunny day.
ƽ WARNING: If the side burner does not light:
1) Turn OFF the side burner control valve.
2) Wait 5 minutes to let the gas clear before you
try again or try to light with a match.
