Weber 42377 Burner User Manual


 
7
Regulator
Hard piped
gas supply
top view
Figure 1
Cap
(Optional
Side Burner)
Regulator
to side burner
Hard piped
gas supply
top view
Figure 2
CONNECT GAS SUPPLY
1) Uncap the fl are fi tting from the optional side burner
connection located at regulator.
Note: You must connect your side burner to a Weber
®
approved regulator(part number #62434) located at
main gas supply. If you do not use a Weber
®
approved
regulator the Warranty on the Summit
®
Built-In Side
Burner will be voided.
If you have any questions, contact Customer Service
at 1-800-446-1071
2) Connect the corrugated gas line to the side burner
Connection.
GAS INSTRUCTIONS
ƽWARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fi tting.
Note - All factory-made connections have been thoroughly
checked for gas leaks. As a safety precaution however,
you should recheck all fi ttings for leaks before using your
Summit
®
Built-In side burner. Shipping and handling may
loosen or damage a gas fi tting.
You will need: a soap and water solution, and a rag or
brush to apply it.
Turn on gas supply.
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows, there is a leak.
Note - Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
ƽWARNING: Do not ignite burners when leak check-
ing.
TEST CONNECTIONS
All connections and joints must be thoroughly tested
for leaks in accordance with local codes and all listed
procedures in the latest edition of the National Fuel Gas
Code ANSI Z223.1/NFPA 54.
ƽ DANGER
Do not use an open fl ame to check for gas leaks.
Be sure there are no sparks or open fl ames in
the area while you check for gas leaks. This will
result in a fi re or explosion which can cause
serious bodily injury or death, and damage to
property.
REGULATOR
The regulator should be adequately supported.
The regulator must be installed close to the appliance.
Each appliance must have a separate regulator.
Test connections
All connections and joints must be thoroughly
tested for leaks in accordance with local codes
and all listed procedures in the latest edition of
ANSI Z223.1/NFPA 54.
ƽDANGER
Do not use an open fl ame to check for gas leaks.
Be sure there are no sparks or open fl ames in
the area while you check for gas leaks. This will
result in a fi re or explosion which can cause
serious bodily injury or death, and damage to
property.