Mounting Guidelines
Temperature <200°C (392°F): bond with high-temperature
epoxy adhesive
Temperature >200°C (392°F): screw hole can be provided
(recommend insulation buffer such as mica spacer)
Clamp using single or multiple-point fasteners
Optional Thermocouple
Bonded bare wire Type K thermocouple with ceramic
insulation for <400°C (752°F)
Drilled hole can be provided for installing a sheathed
thermocouple for <600°C (1112°F)
Lead Wire and Terminations
Power terminals exit locations - extended from side on
square and rectangular shapes and from the top on the
ring shapes
Flexible lead extension
Teflon
®
insulated silver-plated copper lead extension
Lead extension length - standard length 305 mm (12 in.)
How to Order
To order your standard ULTRAMIC 600 heater, please specify
Watlow code number.
If our standard units do not meet your application needs,
Watlow can rapidly manufacture the ULTRAMIC 600 to your
special requirements. For made-to-order units, please consult
the factory.
Availability
Standard heaters are available for shipment in seven business
days or less. While normally customized for the application,
these products enable a development engineer to quickly and
easily acquire a test sample to determine its suitability in the
application.
Custom configurations involving grooves, holes, product
size or surface finishes are routinely manufactured to meet
the exact requirements of the design engineer. Delivery is
dependent on complexity of order. Please consult factory.
Standard Product Ordering Information
FEN-ULT-1007
Square
CER-1-01-00002 25 mm x 25 mm x 2.5 mm 967 1000 (155.04) 240
(0.98 in. x 0.98 in. x 0.1 in.)
CER-1-01-00006 50 mm x 50 mm x 2.5 mm 1938 500 (77.52) 240
(1.97 in. x 1.97 in. x 0.1 in.)
CER-1-01-00093 25 mm x 25 mm x 2.5 mm 150 150 (24) 120
(0.98 in. x 0.98 in. x 0.1 in.)
CER-1-01-00097 19 mm x 19 mm x 2.5 mm 200 357 (55.56) 120
(0.75 in. x 0.75 in. x 0.1 in.)
Rectangular
CER-1-01-00001 25 mm x 15 mm x 2.5 mm 580 1000 (155.04) 120
(0.98 in. x 0.6 in. x 0.1 in.)
CER-1-01-00003 50 mm x 10 mm x 2.5 mm 582 750 (116.28) 120
(1.97 in. x 0.39 in. x 0.1 in.)
CER-1-01-00004 50 mm x 10 mm x 2.5 mm 770 1000 (155.04) 240
(1.97 in. x 0.39 in. x 0.1 in.)
CER-1-01-00005 50 mm x 25 mm x 2.5 mm 1453 750 (116.28) 240
(1.97 in. x 0.98 in. x 0.1 in.)
CER-1-01-00007 75 mm x 25 mm x 2.5 mm 1455 500 (77.52) 240
(2.95 in. x 0.98 in. x 0.1 in.)
CER-1-01-00098 25 mm x 15 mm x 2.5 mm 180 305 (48.0) 120
(0.98 in. x 0.6 in. x 0.1 in.)
CER-1-01-00105 50 mm x 25 mm x 2.5 mm 100 50 (8) 120
(1.97 in. x 0.98 in. x 0.1 in.)
Ring
CER-1-02-00001 38 mm O.D./29 mm I.D. 733 1000 (155.04) 120
(1.50 in. O.D./1.14 in. I.D.)
CER-1-02-00002 77.5 mm O.D./59 mm I.D. 770 250 (38.76) 240
(3.05 in. O.D./2.32 in. I.D.)
Code Voltage
Number Size Watts W/in
2
(W/cm
2
)VÅ(ac)
Leads exit short side
Leads exit top
Standard configurations include:
• Power lead wires with Teflon
®
insulation 305 mm (12 in.)
• Bonded Type K thermocouple with 305 mm (12 in.) Teflon
®
insulated lead extension
• Surface finish (Ra) <0.8 µm (32 µ-in.)
Teflon
®
is a registered trademark of E.I. du Pont Nemours & Company.
To be automatically connected to the nearest North American Technical and Sales Office call:
1-800-WATLOW2
International Technical and Sales Offices: Australia, +61-3-9335-6449 • China, +86-21-3950-9510 • France, +33 (0) 3073-2425 •
Germany, +49 (0) 7253-9400-0 • Italy, +39 (0) 2 458-8841 • Japan, +81-3-3518-6630 • Korea, +82-2-575-9804 • Malaysia, +60-3-7980-7741 •
Mexico, +52 (442) 217-6235 • Shanghai, +86-21-3950-9504 • Singapore, +65-6773-9469 • Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66 •
Taiwan, +886-7-288-5168 • United Kingdom, +44 (0) 115-964-0777