21
105500
OWNER’S MANUAL
CLEANING AND
MAINTENANCE
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: You must keep con-
trol areas, burners, and circulat-
ing air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
WARNING: Do not use abra-
sive cleaners as this may damage
glass. Use a non-abrasive house-
hold glass cleaner to clean glass.
Do not clean glass when hot.
WARNING: Handle glass
door panel with care. Do not
strike, slam or otherwise abuse
glass. Do not operate fireplace
with the glass door removed,
cracked, or broken.
GLASS DOOR
Glass must be cleaned periodically. During
start-up it is normal for condensation to
form on the inside of the glass causing lint,
dust, and other airborne particles to cling to
the glass surface. During initial start-up a
slight film may form on the glass due to
paint curing. The glass should be cleaned
several times with a non-amonia, non-abra-
sive household cleaner and warm water
after the first two weeks of operation. There-
after, clean the glass two or three times
during each heating season, depending on
the usage and circumstances present. Refer
to Removing/Replacing Glass Door on page
16 of this manual when removing glass door
for cleaning.
PILOT AND BURNERS
Remove ember material before clean-
ing burners and replace when cleaning
is complete.
Burner and controls should be cleaned
with compressed air to remove dust, dirt,
or lint.
Use a vacuum cleaner or small, soft
bristled brush to remove excess dust, dirt,
or lint.
WARNING: Only parts sup-
plied by the manufacturer should
be used when replacing broken
or damaged glass door panel (see
Replacement Parts
, page 25). This
glass door panel is a complete
unit. No substitute materials may
be used.
If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door, page 16). Vacuum all glass pieces
with a shop vac.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep chil-
dren and pets away from glass.
WARNING: Do not operate
fireplace with the glass door re-
moved, cracked, or broken.
Use only the ceramic glass door replace-
ment intended for this fireplace (see Re-
placement Parts, page 25 for details on
ordering). No substitutions may be made.
See Removing/Replacing Glass Door, page
16 for instructions for replacing glass door.
CAUTION: Do not vacuum if
pieces are hot.
LOGS
If you remove logs for cleaning, refer to
Installing Logs, Lava Rock, and Glowing
Embers, page 17, to properly replace logs.
Use a vacuum cleaner to remove any car-
bon build-up on logs.
Replace log(s) if broken. See Replace-
ment Parts on page 25.
Replace ember material periodically as
needed. See Replacement Parts on page 25.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced imme-
diately by a qualified service person.
2. Remove the vent cap and shine a
flashlight into the vent. Remove any
foreign material.
3. Check for evidence of excessive con-
densation. Continuous condensation
can cause corrosion of caps, pipes, and
fittings and can be caused by having
excessive lateral runs, too many el-
bows, or exterior portions of the sys-
tem being exposed to cold weather.
4. Inspect joints to verify that no pipe sec-
tion or fitting has been disturbed and
loosened. Check mechanical supports
such as wall straps for rigidity.