Vanguard Heating SBVBN(A) Indoor Fireplace User Manual


 
18
®
B-VENT FREESTANDING FIREPLACE
105500
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2a. Set selector switch in the “OFF”
position.
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to prevent draining battery.
3. Turn off all electrical power to the
appliance if service is to be performed.
4. Push in gas control knob slightly and
turn clockwise to “OFF”.
5. Close lower panel.
Shutting Off Burners Only (pilot
stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
1. Turn control knob clockwise
to the PILOT position.
2. Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/
Replacing Glass Door, page 16).
2. Follow steps 1 through 8 under Light-
ing Instructions.
3. Depress control knob and light pilot
with match.
4. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 10 through 14, column 2.
5. Replace glass door (see Removing/
Replacing Glass Door, page 16).
OPERATING
FIREPLACE
WARNING: If you do not fol-
low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician
to inspect the appliance and to re-
place any part of the control sys-
tem and any gas control which has
been under water.
FOR YOUR SAFETY
READ BEFORE
LIGHTING
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
in column one.
2. Open lower panel.
3. Turn ON/OFF switch to “OFF”.
4. Turn off all electric power to the
fireplace.
5. Push in gas control knob slightly and
turn clockwise to “OFF”.
6. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column one. If you don't
smell gas, go to the next step.
7. The pilot is located by the main
burner and should not require ac-
cessing for lighting.
8. Turn knob on gas control counter-
clockwise to “PILOT”.
9. Push in control knob all the way and
hold. Immediately light the pilot by
repeatedly depressing the piezo
spark ignitor until a flame appears.
Continue to hold for about one (1)
minute after the pilot is lit. Release
knob and it will pop back. Pilot
should remain lit. If it goes out, re-
peat steps 5 through 8.
If knob does not pop up when re-
leased, stop and immediately call your
service technician or gas supplier.
If the pilot will not stay lit after sev-
eral tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.
10. Turn gas control counterclockwise
to “ON”.
11. Turn on all electric power to the
fireplace.
12. Turn the ON/OFF switch to ON
position.
13. This valve is equipped with a HI/LO
feature. Set fireplace input as desired.
14. Close lower panel.
Figure 45 - Control Valve
L
O
H
I
OFF
ON
P
I
L
O
T
Gas Control
Knob
Variable
Control Knob
Piezo Ignitor