Figure 2 – Dimension and Access Data
GENERAL SAFETY INFORMATION
WARNING: RISK OF ELECTRIC SHOCK
These serving instructions are for use by qualified
personnel only, To reduce the risk of electric shock, do
not perform any servicing other than that contained in
the operating instructions unless you are qualified to do
so.
1. Read this manual thoroughly before beginning
the installation of this unit.
2. Conference to all local ordinances associated
with building codes and electrical codes is
required prior to beginning installation of this
unit. Authorities having jurisdiction should be
consulted before installation is made. If there are
no local codes, the installation should conform to
the National Electrical Code.
CAUTION:
The weight of the air cleaner is 150 lbs. Any mounting
arrangement must be able to support this weight. Failure
to determine if mounting is sufficient may result in
damage or injury within the area.
INSTALLATION
Prior to beginning installation, select the location for the
air cleaner. The air cleaner should be located as close to
the contaminant source as possible. The air enters the
air cleaner from the bottom (or specified side with inlet
plenum as viewed from the access door side) and
discharges vertically through the grille in the cabinet top
panel. Do not obstruct the air flow from the unit. Maintain
at least 18 inches (45 cm) clearance above the unit.
MOUNTING
WALL OR VERTICAL SUPPORT MOUNTED
1. Four (4) tapped holes are provided in the
cabinet back. Bars may be mounted to the
cabinet with existing hard ware. The MP600M
can then be mounted to the wall or vertical
support stand (not provided) with 3/8” hardware
(not provided).
2. The inlet plenum is equipped with a ½” half
coupling to connect drain piping. Plumbing
should be routed to the collection point to
facilitate drainage.
3. Affix duct(s) or elbow fitting(s) or flex hose(s) to
the inlet plenum flange collar using hose clamps
or other similar connection method. (Clamps,