Trion 600M Air Cleaner User Manual


 
2
DESCRIPTION
The Trion MP 600M air cleaner is designed to capture
machine tool fluids, metal dust and smoke for clean air
filtration. It can be mounted to a wall, frame, platform, or
directly on the machine tool. Mist, dust, and smoke are
drawn from each machine through an external duct into
the air cleaner. A self-draining Impinger removes the
heavy mist and droplets (including water soluble fluids),
and the remaining contaminates are captured by the pre-
filter and the primary filter. Clean air is returned to the
plant through the vertical discharge. The air cleaner
operates at 95-99.97% efficiency at the rated 600 CFM
airflow.
NEW UNIT INSPECTION
At the time the unit is received, all shipping containers
and their contents should be examined for damage. Any
damage occurring in shipment must be immediately
reported to the carrier, an inspection report completed
and a claim filed at the receiving point. The unit cabinet
is shipped completely assembled
POSITION AIR CLEANER CABINET
To reduce weight for ease in handling, remove the pre-
filters, main filters and place them safely aside. Position
the cabinet in the designated location giving
consideration to following points:
(a) Provide sufficient clearance in front of the
access doors for mechanical filter replacement.
A minimum of 26” is required (see figure 2).
(b) Level the cabinet to assure proper drainage from
the drain pan.
(c) Unless specific design features have been
prearranged, the direction of air flow through th
e cabinet may be from any side or upward
through the bottom. When the filters are
reinstalled, the directional arrows on the filters
must concur with airflow through the cabinet. If
mist suppressors have been specified, they are
to be installed on the air entering side of the unit.
After the cabinet has been properly located, it may be
secured into place at the mounting pads either by bolting
or welding.