Trane XB200 Thermostat User Manual


 
Page - 17
Pub. No. 22-5204-01
Table 1
Comfort Control Setup
Menu Item
Factory
Setting
Setting (Choices)
(Press UP or DOWN arrow)
Step
(Press
Mode or
Fan)
Menu Item
Factory
Setting
Setting (Choices)
(Press UP or DOWN
arrow)
Step
(Press Mode or Fan)
Temperature
Display
0
0 = Fahrenheit
1 = Celcius
40
Energy Savings -
Heating Setpoint
Offset
5
1 - 45 Degrees Fahrenheit
1 - 25 Degrees Celcius
46
Auto or Manual
Changeover
1
0 = Manual
1 = Auto
41
Indoor Filter Timer
Method
0
0 = Calendar Days
1 = Fan Run Time Days
47
Setpoint Deadband 3 2 - 10 Degrees 42
Indoor Filter
Reminder - Days
30
1 - 180 Days
0 = Disable
48
Waiting Icon 1
0 = Disable
1 = Enable
43
Calibrate Indoor
Temperature
0
Calibrated Room Temperature
+ / - 5 Degrees (1/2 degree
increments)
49
Cooling Droop 1
0 = Off
1 = 1 Degree
2 = 2 Degrees
44
Exit Setup
(Press Mode)
SA
SA = Save
US = Default User Settings
CA = Cancel
99
(Exit)
Energy Savings -
Cooling Setpoint
Offset
5
1 - 25 Degrees Fahrenheit
1 - 15 Degrees Celcius
45
Note: Pressing the Energy Savings Key ($) anytime during setup will advance to step 99.
Step 99 - Make setting selection and then press MODE to exit.
SA
ve = Save selections
US
er = Default user settings
CA
ncel = Cancel Selections for current session and return to previous session selections.
Lock - Unlock Keypad:
Press and hold Up Arrow and Down Arrow at the same time.
(“Keypad Locked” icon will display on LCD screen)
User
Setup
Options
(cont-)