Trane XB200 Thermostat User Manual


 
Page - 14
Pub. No. 22-5204-01
Features
(cont-)
Service Indicator
“SERVICE” automatically flashes when an internal fault or error has been detected by the
control. See Table 2 on pages 18.
Wait Indicator
“WAITING” will illuminate when the indoor setpoint is moved in the direction of calling
for additional system capacity. “WAITING” idicates that the control is adjusting to the new
settings.
Calibrate Indoor Temperature
This option allows calibration (or deliberate miscalibration) of the room temperature sensor.
The selection is the number of degrees added to actual temperature. The number can range
between + 5 and - 5. Factory default is 0. This adjusted value will be used as actual tempera-
ture for both display and control action. For example, if 2 is selected, 72 degrees actual will
read 74 degrees.
Comfort Information Drawer
The drawer attached to the mounting base of the control is designed to provide a convenient
location for the home owner to locate their local servicer. A standard business card can be
folded and inserted into the slot on the drawer to remind the User whom to call when service
is required.