Table E2: WPVJ Electrical Performance (High Static Blower Option-continued)
Table E3: WPHF Electrical Performance (Standard Static Blower Option)
Model No.
Volts/Hz/Ph
Total
FLA
Comp.
RLA (ea)
Comp.
LRA (ea)
No. of
Compres.
Cmp
MCC
Blower
Motor
FLA
Blower
Motor
HP
Fan Motor
Num
Minimum
Circuit
Ampacity
Overcurrent
Protective
Device
Desup Desup
RLA
WPVJ060 208/60/1 33.5 28.00 169.0 1 39.0 5.50 3/4 1 40.5 60 No 0
WPVJ060 208/60/1 33.71 28.00 169.0 1 39.0 5.50 3/4 1 40.7 60 Yes 0.21
WPVJ060 208/60/3 24.8 19.30 123.0 1 27.0 5.50 3/4 1 29.6 45 No 0
WPVJ060 208/60/3 25.01 19.30 123.0 1 27.0 5.50 3/4 1 29.8 45 Yes 0.21
WPVJ060 230/60/1 33.5 28.00 169.0 1 39.0 5.50 3/4 1 40.5 60 No 0
WPVJ060 230/60/1 33.71 28.00 169.0 1 39.0 5.50 3/4 1 40.7 60 Yes 0.21
WPVJ060 230/60/3 24.8 19.30 123.0 1 27.0 5.50 3/4 1 29.6 45 No 0
WPVJ060 230/60/3 25.01 19.30 123.0 1 27.0 5.50 3/4 1 29.8 45 Yes 0.21
WPVJ060 380-415/50/3 10.8 7.50 49.5 1 10.5 3.30 3/4 1 12.7 20 No 0
WPVJ060 460/60/3 10.8 7.50 49.5 1 10.5 3.30 3/4 1 12.7 20 No 0
WPVJ060 460/60/3 11.01 7.50 49.5 1 10.5 3.30 3/4 1 12.9 20 Yes 0.21
WPVJ060 575/60/3 8.9 6.40 40.0 1 9.0 2.50 3/4 1 10.5 15 No 0
WPVJ060 575/60/3 9.11 6.40 40.0 1 9.0 2.50 3/4 1 10.7 15 Yes 0.21
WPVJ072 208/60/1 37.6 32.10 169.0 1 45.0 5.50 3/4 1 45.6 70 No 0
WPVJ072 208/60/1 37.81 32.10 169.0 1 45.0 5.50 3/4 1 45.8 70 Yes 0.21
WPVJ072 208/60/3 24.8 19.30 137.0 1 27.0 5.50 3/4 1 29.6 45 No 0
WPVJ072 208/60/3 25.01 19.30 137.0 1 27.0 5.50 3/4 1 29.8 45 Yes 0.21
WPVJ072 230/60/1 37.6 32.10 169.0 1 45.0 5.50 3/4 1 45.6 70 No 0
WPVJ072 230/60/1 37.81 32.10 169.0 1 45.0 5.50 3/4 1 45.8 70 Yes 0.21
WPVJ072 230/60/3 24.8 19.30 137.0 1 27.0 5.50 3/4 1 29.6 45 No 0
WPVJ072 230/60/3 25.01 19.30 137.0 1 27.0 5.50 3/4 1 29.8 45 Yes 0.21
WPVJ072 380-415/50/3 13.3 10.00 62.0 1 14.0 3.30 3/4 1 15.8 25 No 0
WPVJ072 460/60/3 13.3 10.00 62.0 1 14.0 3.30 3/4 1 15.8 25 No 0
WPVJ072 460/60/3 13.51 10.00 62.0 1 14.0 3.30 3/4 1 16.0 25 Yes 0.21
WPVJ072 575/60/3 10.4 7.90 50.0 1 11.0 2.50 3/4 1 12.4 20 No 0
WPVJ072 575/60/3 10.61 7.90 50.0 1 11.0 2.50 3/4 1 12.6 20 Yes 0.21
Model No.
Volts/Hz/Ph
Blower Motor
HP
Blower Motor
FLA
Compr.
RLA
Compr.
MCC
Compr.
LRA
Minimum Cir-
cuit Amps
UL Max Fuse
or HACR
CSA
Max. Fuse
Size
CASE
Max.
Circuit Brkr
WPHF021 208/60/1 1/8 1.3 8.0 12.5 45 11.3 15 20 15
WPHF021 230/60/1 1/8 1.3 8.0 12.5 45 11.3 15 20 15
WPHF021 265/60/1 1/8 1.1 7.0 10.9 39 9.9 15 20 15
WPHF027 208/60/1 1/5 1.2 11.0 17.2 60 15.0 25 30 25
WPHF027 230/60/1 1/5 1.2 11.0 17.2 60 15.0 25 30 25
WPHF027 265/60/1 1/5 2.4 9.6 15.0 52 14.4 20 25 20
WPHF035 208/60/1 1/5 2.0 12.4 19.4 65 17.5 30 35 25
WPHF035 230/60/1 1/5 2.0 12.4 19.4 65 17.5 30 35 25
WPHF035 265/60/1 1/5 2.4 10.8 16.9 57 15.9 25 30 25
WPHF040 208/60/1 1/3 2.8 15.1 23.5 85 21.7 35 45 35
WPHF040 230/60/1 1/3 2.8 15.1 23.5 85 21.7 35 45 35
WPHF040 265/60/1 1/3 2.0 13.2 20.5 74 18.5 30 40 30
WPHF040 208/60/3 1/3 2.8 10.6 16.5 101 16.1 25 50 40
WPHF040 230/60/3 1/3 2.8 10.6 16.5 101 13.1 25 50 40
WPHF040 265/60/3 1/3 2.0 4.2 6.6 51 7.3 15 25 20
WPHF047 208/60/1 1/3 2.8 14.6 22.8 92 21.1 35 50 40
WPHF047 230/60/1 1/3 2.8 14.6 22.8 92 21.1 35 50 40
WPHF047 208/60/3 1/3 2.8 10.6 16.5 101 16.1 25 50 40
WPHF047 230/60/3 1/3 2.8 10.6 16.5 101 16.1 25 50 40
WPHF047 460/60/3 1/3 1.1 4.2 6.6 51 6.4 15 25 20