22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 7
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
TUD2C100A9V5VB
Upflow / Horizontal
65,000
52,000
100,000
79,000
35 - 65
Direct
10 x 10
1
Variable
See Airflow Table
1
Variable
115/1/60
Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.87
Yes
High Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel - Type 1
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot
5
115/1/60
14.9
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
166 / 155
TUD2B100A9V3VB
Upflow / Horizontal
65,000
52,000
100,000
80,000
40 - 70
Direct
10 x 7
1
Variable
See Airflow Table
1/2
Variable
115/1/60
Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.87
Yes
High Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel - Type 1
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot
5
115/1/60
10.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
142 / 132
TUD-R9V PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,
above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5 Model uses high efficiency blower.
TUD2C080B9V4VB 5
Upflow / Horizontal
52,000
41,600
80,000
64,000
30 - 60
Direct
10 x 10
1
Variable
See Airflow Table
3/4
Variable
115/1/60
Centrifugal
Direct - 2
1/50 - 3000
115/1/60
0.7
Yes
High Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel - Type 1
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot
4
115/1/60
12.9
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
166 / 155