*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW7 SW8 0.1 0.3 0.5 0.7 0.9
HEATING
1ST
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
1007
57
114
1062
54
177
1084
53
285
1063
54
303
1063
54
350
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1154
50
167
1211
48
230
1211
48
277
1221
47
344
1212
48
417
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1288
45
208
1319
44
273
1310
44
330
1349
43
410
1358
43
460
HEATING
2ND
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
1387
64
250
1421
63
320
1455
61
400
1488
60
460
1495
59
540
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1589
56
350
1637
54
440
1666
53
535
1678
53
600
1541
58
575
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1771
50
475
1788
50
560
1804
49
650
1751
51
675
1554
57
590
*UD2D120A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9
3.5
LOW
(350 CFM/ TON)
OFF ON OFF ON
CFM
WATTS
1195
150
1243
225
1235
275
1251
325
1251
410
NORMAL
(400 CFM/ TON)
OFF ON OFF OFF
CFM
WATTS
1353
210
1403
290
1417
370
1437
425
1458
485
HIGH
(450 CFM/ TON)
OFF ON ON OFF
CFM
WATTS
1554
315
1572
410
1615
480
1634
570
1567
575
4
LOW
(350 CFM/ TON)
ON OFF OFF ON
CFM
WATTS
1356
200
1391
280
1399
370
1433
420
1454
510
NORMAL
(400 CFM/ TON)
ON OFF OFF OFF
CFM
WATTS
1565
320
1584
410
1633
475
1639
560
1554
575
HIGH
(450 CFM/ TON)
ON OFF ON OFF
CFM
WATTS
1766
450
1799
550
1810
650
1784
685
1590
600
5 **
LOW
(350 CFM/ TON)
OFF OFF OFF ON
CFM
WATTS
1708
420
1758
530
1759
585
1775
675
1575
585
NORMAL **
(400 CFM/ TON)
OFF OFF OFF OFF
CFM
WATTS
1994
665
2018
775
1971
785
1814
725
1618
625
HIGH
(450 CFM/ TON)
OFF OFF ON OFF
CFM
WATTS
2247
975
2152
925
2019
860
1861
765
1693
680
NOTES: "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON".
1. *FIRST LETTER MAY BE "A" OR "T"
2. **FACTORY SETTING.
3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE.
4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING:
NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.