14 DATA SUBJECT TO CHANGE WITHOUT NOTICE 22-1650-13
*UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING
1ST
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
900
53
100
890
54
130
870
55
175
850
57
220
835
58
270
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1125
43
150
1090
44
200
1060
46
235
1070
45
300
1070
45
340
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1300
37
220
1300
37
290
1320
36
365
1350
36
430
1340
36
490
HEATING
2ND
STAGE
LOW ON ON
CFM
TEMP. RISE
WATTS
1270
59
200
1290
58
260
1290
58
335
1290
58
400
1280
58
460
MEDIUM ** ON OFF
CFM
TEMP. RISE
WATTS
1575
47
355
1600
46
445
1610
46
520
1600
46
575
1580
47
650
HIGH OFF OFF
CFM
TEMP. RISE
WATTS
1870
40
560
1890
39
665
1860
40
710
1870
40
830
1730
43
760
*UD2C100A9V5VB FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.0
LOW
(350 CFM/TON)
ON ON OFF ON
CFM
WATTS
1075
135
1055
185
1015
220
1000
265
990
325
NORMAL
(400 CFM/TON)
ON ON OFF OFF
CFM
WATTS
1220
185
1200
240
1210
295
1210
350
1210
410
HIGH
(450 CFM/TON)
ON ON ON OFF
CFM
WATTS
1390
245
1390
320
1410
391
1410
470
1400
510
3.5
LOW
(350 CFM/TON)
OFF ON OFF ON
CFM
WATTS
1214
185
1210
240
1215
295
1210
350
1210
415
NORMAL
(400 CFM/TON)
OFF ON OFF OFF
CFM
WATTS
1430
310
1460
355
1470
430
1460
500
1440
555
HIGH
(450 CFM/TON)
OFF ON ON OFF
CFM
WATTS
1640
370
1665
460
1650
540
1640
615
1610
660
4.0
LOW
(350 CFM/TON)
ON OFF OFF ON
CFM
WATTS
1405
270
1430
310
1440
375
1440
480
1420
550
NORMAL
(400 CFM/TON)
ON OFF OFF OFF
CFM
WATTS
1670
395
1675
490
1670
550
1655
630
1630
700
HIGH
(450 CFM/TON)
ON OFF ON OFF
CFM
WATTS
1870
540
1880
635
1880
730
1845
800
1670
640
5.0 **
LOW
(350 CFM/TON)
OFF OFF OFF ON
CFM
WATTS
1775
480
1800
580
1820
680
1800
750
1680
740
NORMAL **
(400 CFM/TON)
OFF OFF OFF OFF
CFM
WATTS
2065
755
2020
840
1945
900
1805
880
1623
800
HIGH
(450 CFM/TON)
OFF OFF ON OFF
CFM
WATTS
2310
1000
2100
1000
2100
950
1965
890
1800
825
NOTES:
1. * First letter may be "A" or "T"
2. ** Factory setting
3. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value.
4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting