Trane TCONT800AS11AA Air Conditioner User Manual


 
TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL
69-1787-1 4
Pub. No. 18-HD25D18-1
Powering the Comfort Control
The comfort control can be powered with 24 Vac.
24 Vac Common Power (Recommended)
Wire the common side of the transformer to the B screw
of the comfort control wallplate. When installing in a
single transformer system, keep the jumper wire between
the R and Rc screws. When installing in a two-
transformer system, use the common from the cooling
transformer to connect to the B screw and remove the
jumper wire between the R and Rc screws.
Battery Power (Optional)
CAUTION
Equipment or Property Damage Hazard.
Using battery power only may not provide
adequate power to comfort control and can
cause damage during freezing conditions.
Connect the 24 Vac Common (B) wire from the
system transformer to the comfort control for
proper operation when the battery power is
drained.
Three AAA alkaline batteries can be used to power the
comfort control for armchair programming only. To
prevent the comfort control and heating/cooling system
from shutting down due to lack of battery power, it is not
recommended that the comfort control be solely powered
with the three AAA batteries during normal system
operation. When using batteries, make sure positive and
negative terminals are oriented correctly, as marked on
the device. See Fig. 8.
Fig. 8. Installing batteries on comfort control back.
Mounting the Comfort Control
1. Align the terminal screw blocks with the pins on the
back of the comfort control.
2. Push the comfort control straight onto the wall-
plate. See Fig. 9.
Fig. 9. Mounting comfort control on wallplate.
Adjusting Real-Time Clock
Setting Calendar and Time
Locate and remove the tab labeled Remove in the lower
left corner on the comfort control back. The tab must be
removed to activate the real-time clock. See Fig. 10.
Fig. 10. Removing tab to activate real-time clock.
This comfort control is designed to automatically keep
current time and day in memory for up to ten years under
normal use after calendar is set. When comfort control is
first powered, display is ready to enter calendar date.
See Fig. 11.
M19918
BATTERIES (3)
WALL
M22643
REMOVE DURING
INSTALLATION
REMOVE DURING
INSTALLATION
M22644
REMOVE TAB TO ACTIVATE REAL TIME CLOCK
REMOVE DURING
INSTALLATION