Trane TCONT800AS11AA Air Conditioner User Manual


 
TCONT800AS11AA TOUCH SCREEN PROGRAMMABLE COMFORT CONTROL
11 69-1787-1
Pub. No. 18-HD25D18-1
SYSTEM CHECKOUT
Installer System Test
The Installer System Test mode is used to test the HVAC
system(s). See Table 5. While in System Test mode,
minimum off -time for compressors is bypassed.
The Installer Test is part of Installer Setup options. Enter
Installer Setup screen and press Down arrow key to bring
up test selection(s) quickly.
ADVANCED FEATURES
Outdoor or Indoor Temperature Sensor
For accuracy, the initial reading of the indoor or outdoor
temperature sensor requires fives minutes to stabilize.
See the Sensor instructions for installation information.
CAUTION
Equipment Damage Hazard.
Minimum compressor off-time is bypassed
during Installer System Test.
Avoid cycling compressor quickly.
Table 5. System Test(s).
Select
Installer
Setup
Number
Factory Setting Other Choices
CommentsOptions Description Options Description
Installer Test
Cool
Test 1 0 Cool is off 1 0—cool off
1—cool stage 1
turns on
System selection deter-
mines tests available and
number of stages shown.
Installer Test
Fan
Test 2 0 Fan is off 1 0—fan off
1—fan turns on
Installer Test
Heat
Test 3 0 Heat is off 1 0—heat off
1—stage 1heat on