Trane GAT2A0C48S41SA Air Conditioner User Manual


 
Pub. No. 22-1857-03 9
Performance
Data
GAT2A0C60 AIRFLOW PERFORMANCE TABLE
AIRFLOW PERFORMANCE
GAT2A0C60S51SA
EXTERNAL STATIC
(in w.g)
AIRFLOW (CFM)
Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS
5 4 3 2 1 5 4 3 2 1
0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629
0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582
0.2 2130 1889 1803 1667 1554 2121 1961 1795 1659 1545
0.3 2102 1850 1774 1628 1523 2090 1919 1763 1617 1511
0.4 2066 1818 1741 1596 1491 2052 1884 1727 1582 1477
0.5 2015 1785 1707 1564 1457 1998 1848 1690 1547 1440
0.6 1959 1754 1673 1520 1408 1939 1814 1653 1500 1389
0.7 1888 1716 1638 1477 1372 1880 1774 1615 1455 1349
0.8 1811 1680 1605 1440 1323 1820 1735 1580 1415 1298
0.9 1750 1628 1561 1403 1291 1770 1680 1533 1376 1263
1.0 1680 1604 1533 1368 1256 1725 1654 1503 1337 1226
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. † Factory Setting
GAT2A0C60S51SA MINIMUM HEATER AIRFLOW CFM
Heater Minimum Air Speed Tap
With Heat Pump Without Heat Pump
BAYEAAC05BK1AA
BAYEAAC05LG1AA
Tap 2 Tap 2
BAYEAAC08BK1AA
BAYEAAC08LG1AA
Tap 3 Tap 2
BAYEAAC10BK1AA
BAYEAAC10LG1AA
Tap 3 Tap 2
BAYEABC15BK1AA Tap 4 Tap 3
BAYEABC20BK1AA Tap 4 Tap 3
BAYEACC25BK1AA Tap 5 Tap 4
SEE AIR HANDLER NAMEPLATE FOR ADDITIONAL INFORMATION
Note: Heating and cooling
speeds are the same, factory
set at Speed Tap #4 for the
CTM motor.