Trane Fan Fan User Manual


 
42
Fan Size 49”
Wheel Dia. 49.0 inches 1245 mm
Inlet Area 14.96 square feet 1.390 m
2
Outlet Area 14.96 square feet 1.390 m
2
Tip Speed 12.83 x RPM 3.911
ft./minute m/minute
Minimum Fan RPM (Without VFRB Option)
Motor Minimum Fan RPM
1800 RPM 301
1200 RPM 201
Performance
Data
Q Fan
Size 49
Table P-11 — Size 49 Q-Fan
CFM Out- Total Static Pressure
Std. let
1
/4
3
/8
1
/2
5
/8
3
/4 1 1
1
/4 1
1
/2 1
3
/4 2
Air Vel. RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
13000 868 353 1.0 376 1.2 400 1.6 425 1.9 451 2.3
14000 935 373 1.1 395 1.4 417 1.7 439 2.1 463 2.4
15000 1002 394 1.3 414 1.6 435 1.9 455 2.3 476 2.6 521 3.5
160001069 415 1.4 434 1.8 453 2.1 472 2.5 492 2.9 532 3.7
17000 1136 437 1.6 454 2.0 472 2.4 490 2.7 508 3.1 545 4.0 585 4.9
18000 1203 458 1.9 475 2.2 492 2.6 509 3.0 525 3.4 560 4.3 596 5.2
19000 1270 480 2.1 496 2.5 511 2.9 528 3.3 544 3.7 576 4.6 610 5.6 645 6.6
20000 1336 503 2.4 517 2.8 532 3.2 547 3.6 563 4.1 593 4.9 624 5.9 657 7.0 691 8.1
21000 1403 525 2.7 539 3.1 552 3.5 567 3.9 582 4.4 611 5.3 640 6.3 671 7.4 702 8.5
22000 1470 548 3.0 560 3.4 574 3.9 587 4.3 601 4.8 629 5.8 657 6.7 685 7.8 715 9.0 745 10.2
23000 1537 570 3.4 582 3.8 595 4.2 608 4.7 621 5.2 648 6.2 674 7.2 701 8.3 729 9.5 757 10.7
240001604 593 3.7 605 4.2 616 4.6 629 5.1 641 5.6 667 6.7 692 7.7 718 8.8 744 10.0 771 11.2
25000 1671 616 4.2 627 4.6 638 5.1 650 5.6 662 6.1 686 7.2 711 8.3 735 9.3 760 10.5 785 11.8
26000 1737 639 4.6 649 5.1 660 5.6 671 6.1 682 6.6 706 7.7 730 8.8 753 9.9 777 11.1 801 12.4
27000 1804 662 5.1 672 5.6 682 6.1 693 6.6 704 7.1 726 8.2 749 9.4 772 10.6 794 11.8 817 13.0
28000 1871 685 5.6 695 6.1 704 6.6 715 7.1 725 7.7 746 8.8 768 10.0 790 11.3 812 12.5 834 13.7
29000 1938 708 6.1 717 6.6 727 7.2 737 7.7 746 8.3 767 9.5 788 10.7 809 12.0 830 13.2 851 14.5
30000 2005 731 6.7 740 7.2 749 7.8 759 8.3 768 8.9 788 10.1 808 11.4 828 12.7 849 14.0 869 15.3
31000 2072 754 7.3 763 7.9 772 8.4 781 9.0 790 9.6 809 10.8 828 12.1 848 13.5 868 14.8 888 16.2
32000 2139 777 8.0 786 8.6 794 9.1 803 9.7 812 10.3 830 11.6 848 12.9 867 14.2 887 15.6 906 17.1
33000 2205 801 8.7 809 9.3 817 9.9 826 10.5 834 11.1 851 12.4 869 13.7 887 15.1 906 16.5 925 18.0
34000 2272 824 9.4 832 10.0 840 10.6 848 11.2 856 11.9 873 13.2 890 14.5 908 15.9 926 17.4 944 18.9
35000 2339 847 10.2 855 10.8 863 11.4 871 12.1 879 12.7 895 14.1 911 15.4 928 16.9 946 18.4 964 19.9
36000 2406 871 11.0 878 11.7 886 12.3 893 13.0 901 13.6 917 15.0 933 16.4 949 17.8 966 19.3 983 20.9
CFM Out- Total Static Pressure
Std. let 2
1
/4 2
1
/2 3 3
1
/2 4 4
1
/2 5 5
1
/2 6 6
1
/2
Air Vel. RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
23000 1537 787 12.0
24000 1604 798 12.6 827 13.9
25000 1671 811 13.1 838 14.5
26000 1737 825 13.8 851 15.2 903 18.1
27000 1804 840 14.4 864 15.8 913 18.8
28000 1871 856 15.1 879 16.5 925 19.5 974 22.8
29000 1938 873 15.8 894 17.3 939 20.3 985 23.6
30000 2005 890 16.6 910 18. 1 953 21.2 996 24.4 1042 27.9
31000 2072 907 17.5 927 18.9 968 22.0 1009 25.3 1053 28.8
32000 2139 925 18.4 944 19.8 983 22.9 1023 26.3 1064 29.7 1107 33.5
33000 2205 944 19.4 962 20.8 999 23.9 1038 27.3 1077 30.8 1118 34.5
34000 2272 962 20.4 980 21.9 1016 24.9 1053 28.3 1091 31.9 1129 35.6 1170 39.5
35000 2339 981 21.4 999 23.0 1033 26.0 1069 29.4 1105 33.0 1143 36.8 1181 40.6 1221 44.8
36000 2406 1000 22.5 1017 24.1 1051 27.2 1085 30.5 1120 34.2 1156 38.0 1192 41.9 1230 46.0
37000 2473 1020 23.6 1036 25.2 1069 28.4 1102 31.7 1136 35.4 1171 39.2 1206 43.2 1242 47.3
38000 2540 1039 24.8 1055 26.4 1088 29.8 1120 33.0 1152 36.6 1186 40.5 1220 44.5 1254 48.6
39000 2606 1058 25.9 1075 27.6 1106 31.1 1137 34.4 1169 38.0 1201 41.9 1234 45.9
40000 2673 1078 27.1 1094 28.9 1125 32.4 1155 35.8 1186 39.4 1217 43.3 1249 47.4
41000 2740 1099 28.4 1114 30.2 1144 33.8 1174 37.5 1203 40.9 1234 44.8 1264 48.9
42000 2807 1119 29.8 1133 31.6 1163 35.3 1193 39.0 1221 42.5 1251 46.4
43000 2874 1140 31.2 1154 33.0 1183 36.8 1211 40.6 1240 44.3 1268 48.0
44000 2941 1160 32.6 1174 34.5 1202 38.3 1230 42.2 1258 46.1
45000 3008 1181 34.2 1195 36.0 1222 39.8 1250 43.8
46000 3074 1202 35.7 1215 37.6 1241 41.5 1269 45.5
Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar).
Performance shown is for installation Type B: free inlet, ducted outlet.
Power rating (BHP) does not include drive losses.
Performance ratings do not include the effects of appurtenances in the airstream.
When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent.
Fan tables cover part of fan operating range; fan curves show full operating range.
Pressure Class Limits
Class Maximum RPM
I 949
II 1274