– 154 –
No.
1
Part name
Common
procedure
Procedure
CAUTION
Be sure to put on the gloves at working time;
otherwise an injury may be caused by a part,
etc.
1. Detachment
1) Stop operation of the air conditioner and then
turn off switch of the breaker.
2) Remove the front panel.
(Hexagonal screw Ø4 × 10, 2 pcs.)
∗ After removing screws, remove the front
panel while pulling it downward.
3) Remove the power wire and indoor/outdoor
connecting wire from the cord clamp and the
terminals.
4) Remove the top plate.
(Hexagonal screw Ø4 × 10, 5 pcs.)
2. Attachment
1) Attach the top plate.
(Hexagonal screw Ø4 × 10, 5 pcs.)
In this time, insert the fin guard of rear side
between the top plate and the heat exchanger
(Rear side).
2) Connect the power supply wire and the
indoor/outdoor connecting wire to the terminal
and fix it with cord clamp.
CAUTION
Using bundling band on the market, be sure to
fix the power wire and indoor/outdoor
connecting wire along the crossover pipe so that
they do not come to contact with the
compressor, valve at gas side, pipe at gas side
and discharge pipe.
3) Attach the front panel.
(Hexagonal screw Ø4 × 10, 2 pcs.)
Remarks
14-2-2. RAV-SP804AT-E, RAV-SP804ATZ-E, RAV-SP804ATZG-E
Front panel
Top plate
Insert the fin guard of rear side between
the top plate and the heat exchanger
(at rear side).