Toshiba RAV-SP240CT-UL Air Conditioner User Manual


 
–18–
Under Ceiling Type
Installation Manual
EN
Toshiba
Wire connection
REQUIREMENT
Be sure to connect the wires matching the terminal numbers. Incorrect connection causes a trouble.
The low-voltage circuit is provided for the remote control. (Do not connect the high-voltage circuit)
Loosen the cover mounting screws (2 positions) of the electric parts box, and then remove the cover.
Attach the conduit pipe to the conduit hole with a lock nut.
Slit the film of bushing attached to the hole for remote control wire, and then pass through wires.
Connect the system interconnection wires and the remote control wire to the terminal block of the electric parts
box. Secure the ground wire with the ground screw.
Tighten screws of the terminal block securely, and fix the wires with code clamp attached to the electric parts
box. (Do not apply tension to the connecting section of the terminal block.)
Mount the cover of the electric parts box so that it does not pinch the wires.
A
B
S
L
1
L
2
Electric parts box
P.C. board
Two screws
Terminal block
Ground screw
Remote control wires
Hole for Remote control wires
Conduit hole
Cord clamp
Terminal block for
wired remote
control
Terminal block for system
interconnection
Wire partition plate
Pass the remote control wire through the
hole for remote control wire and behind
this wire partition plate.
System interconnection
wires and ground wire
18-EN
+00EH99864801_00Ta.book Page 18 Tuesday, November 24, 2009 5:40 PM