Toshiba RAV-SM1603ATZ-E Air Conditioner User Manual


 
– 21 –
1-2. Outdoor Unit
Model name
Power supply
Type
Compressor Motor (kW)
Pole
Refrigerant charged (kg)
Refrigerant control
Standard length (m)
Min. length (m)
Inter
Max. total length (m)
Additional refrigerant charge
connecting pipe
under long piping connector
Height
Outdoor lower (m)
difference
Outdoor higher (m)
Height (mm)
Outer dimension Width (mm)
Depth (mm)
Appearance
Total weight (kg)
Heat exchanger
Fan
Fan unit Standard air flow (m³/h)
Motor (W)
Connecting pipe
Gas side (mm)
Liquid side (mm)
Sound pressure level Cooling/Heating (dB•A)
Sound power level Cooling/Heating (dB•A)
Outside air temperature, Cooling C)
Outside air temperature, Heating C)
RAV-SM1603AT(Z)(ZG)-E
1 phase 230V (220 – 240V) 50Hz
Hermetic compressor
3.75
4
3.1
Pulse motor valve
7.5
5
50
40g/m
(31m to 50m)
30
30
1340
900
320
Silky shade (Muncel 1Y8.5/0.5)
99
Finned tube
Propeller fan
103
100 + 100
15.9
9.5
51 / 53
68 / 70
43 to –15
15 to –15