Toshiba RAS-B13GKVP-E Air Conditioner User Manual


 
18
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
6-2. Outdoor Unit
RAS-10GAVP-E, RAS-13GAVP-E, RAS-16GAVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
Type
MF-280-30-5R
( )
( )
MP24Z
Specifications
DC280340V, 30W
10k at 25°C
10k at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outside fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (6P)
Compressor
Coil for P.M.V.
Coil for 4-way valve
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-20F1
CAM-MD12TF
VHV
Rating
L = 10mH, 16A × 2
DC140V, 43W
10k (25°C)
62k (20°C)
10k (25°C)
10k (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220240V