Toshiba RAS-13JKVP-E Air Conditioner User Manual


 
20
EN
Attaching the Zeolite-plus filter and Zeolite-3G filter
After installing the air conditioner, attach the supplied Zeolite-plus
filter and Zeolite-3G filter.
Preparation:
1. Turn off the air conditioner using the remote control.
1 Open the air inlet grille.
Lift up the air inlet grille until it clicks into place.
2 Take off the air filter from the left side.
Grasp the left and right handles of the air filter and lift up slightly and then pull downward to
remove the filter from the filter holder.
3 Attach the Zeolite-plus filter and Zeolite-3G filter to the front panel.
When attaching new filters, remove the Zeolite-plus filter and Zeolite-3G filter from the bag,
and then insert the filters with the Zeolite-plus filter on the top.
4 Attach the air filter, and then close the air inlet grille.
Cleaning the Zeolite-plus filter and Zeolite-3G filter
Clean the filters when you clean the dust collecting unit. (Clean approximately once every six
months.)
Preparation:
1. Turn off the air conditioner using the remote control.
1 Open the air inlet grille.
Lift up the air inlet grille until it clicks into place.
2 Grasp the left and right handles of the air filter and lift up slightly and then pull downward to
remove the filter from the filter holder.
3 Remove the Zeolite-plus filter and Zeolite-3G filter from the front panel.
4 Wash the Zeolite-plus filter and Zeolite-3G filter in water, and then drain.
If the filters are dirty with dust and dirt, use a vacuum cleaner to remove the dirt before
washing with water. Also, be sure to always use clean water when washing. If dirty water is
used, the debris in the water can adhere to the filters.
Do not rub the filter surface.
In the final of the water washing, be sure to always rinse the filter with clean water.
If the filter is particularly dirty, add a neutral detergent at the standard concentration and then
rinse with clean water until there are no more soap bubbles.
Drain gently after washing with water.
5 Allow the Zeolite-plus filter and Zeolite-3G filter to dry in the sun.
It takes about six hours for the filters to dry in direct sunlight.
6 Attach the air filter, and then close the air inlet grille.
SPECIAL MAINTENANCE
INFORMATIONINFORMATION
It is recommended that you replace the filters once
about every six years.
Deodorizing performance will drop when there are
severe stains due to extended periods of usage
such as due to tar accumulation from cigarette
smoke.
Items sold separately
Zeolite-plus filter
(RB-A607DE)
Zeolite-3G filter
(RB-A608DE)
01_EU_RAS-10JKP_EN.fm Page 20 Wednesday, April 9, 2003 8:08 AM