Toshiba RAS-17LKV-UL Air Conditioner User Manual


 
Horizontal
blowing
Inclined
blowing
Blowing
downward
Air direction
Inclined
blowing
Horizontal
blowing
Initial setting of "Cooling storage position"
Louver : Horizontal blowing (37.4°)
Heating operation/
AUTO (HEAT)
Initial setting of Heating storage position
Louver : Directs downward (76.9˚)
Item
8. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
3) Swing
2) Louver position in heating operation
2) Air direction adjustment
The position is automatically controlled according to the operation
The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
mode (COOL/HEAT).
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
The louver position can
be arbitrarily set up by
pressing [FIX] button.
36
FILE NO. SVM-10020
Cooling operation/
AUTO (COOL)
Swing operation is perfor in range 35° with the Fixed position as
the center.
If the swing range exceeded either upper or lower limit position,
swing operation is performed in range 35° from the limit.
Fixed
Position
before start
swing
Upper Limit
Position.
Lower Limit
Position
30
o
5
o
Swing
range 35
o
Upper Limit
Position.
Lower Limit
Position.
Fixed Position
before start
swing.
17.5
o
17.5
o
Swing
range 35
o