Toshiba RAS-09LKV-UL Air Conditioner User Manual


 
89
( RAS-12LKV-UL )
100
30
40
50
60
70
80
90
20
10
0
0102030 4050
Resistance value (k )
Temperature ( C)
TD : Discharge temp. sensor
TA : Room temp. sensor
TC : Heat exchanger temp. sensor
TO : Outdoor temp. sensor
TE : Outdoor heat exchanger temp. sensor
TS : Suction temp. sensor
TA, TC, TO, TE, TS
TD
[1] Sensor characteristic table
FILE NO. SVM-10019