Toshiba RAS-09LKV-UL Air Conditioner User Manual


 
46
9-3-3. Power Failure During Timer Operation
If Timer operation is set and the power supply shut down accidentally, the previous Timer setting
will be cancelled.
Daily-Timer operation will be not affected by power supply failure, if the remote controller is
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is on standby.
The unit starts to operate. The green indicator is on.
After approx. three seconds,
The unit beeps three times The green indicator flashes
and continues to operate. for 5 seconds.
If the unit is not required to operate at this time, press [RESET]
button once more or use the remote controller to turn it off.
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is in operation. The green indicator is on.
The unit stops operating. The green indicator is turned off.
After approx. three seconds,
The unit beeps three times. The green indicator flashes
for 5 seconds.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.
9-3-2. How to Set the Auto Restart Function
To set Auto Restart Function, proceed as follows:
1. The power supply to the unit must be ON ; The function will not set or reset if the power supply is OFF.
2. Press the [RESET] button located on the front panel of the indoor unit for more than 3 seconds.
3. After 3 seconds, the unit beeps three times and the indicator blinks for 5 seconds.
When the unit is standby (Not operating)
When the unit is in operation
While the filter check indicator is on, the RESET button has the function of filter reset betton.
RESET
Hi POWER FILTER PAP TIMER OPERATION
RESET
Hi POWER FILTER PAP TIMER OPERATION
FILE NO. SVM-10019
located on the position which it can send the command signal to the indoor unit. It is because the remote
controller will send signal every 30 minutes and Daily-Timer operation will be restore.