Toshiba RAS-09LKV-UL Air Conditioner User Manual


 
107
No.
Part name
Electronic
expansion valve
coil
Procedure
Wire guard 1. Detachment
1) Perform work of item 1 of
.
2) Remove the front cabinet, and put it down
so that wire guard side directs downward.
Perform work on a corrugated cardboard,
cloth, etc. to prevent flaw to the product.
3) Remove the guard stopper (4 pcs.) from hook
of wire guard.
4) Turn the front cabinet into opposite site then
FILE NO. SVM-10019
pull wire guard up ward.
2. Attachment
1) Insert claws (2 positions) of the wire guard
in the holes of the front cabinet. Push the
hook (4 positions) by hands and fix by
Check that all the claws & hooks are fixed
to the specified positions.
1. Detachment
1) Perform step 1 in
, all the steps in
and 1 in
.
2) Remove the coil by pull it upward.
2. Attachment
1) Insert a valve coil to value body by push
it downward. And confirm to fix it surely.
Remarks
guard stopper.