Toshiba HWS-802XWHT6-E Heat Pump User Manual


 
153
Toshiba
7 Pulse motor valve coil
1. How to remove
1)Perform the step 1-1.
2)Remove the coil from the pulse motor valve body
by pulling upward while rotating the coil.
2. How to attach
1)Fix the coil by exactly adjusting the coil positioning
projection to the recess of the pulse motor valve
body.
8 Fan guard 1.How to remove
1)Perform the step 1-1 and step 2.
Note
Perform a replacement work on cardboard or
cloth to prevent the product from being
damaged.
2)Remove the outlet cabinet and put with the fan
guard side down.
3)Release the hooks (8 positions) of the fan guard.
2.How to attach
1)Press the hooks (8 positions) with hands from the
front side to fix them.
Note
Check that all the hooks are fixed to the given
positions.
No.
Exchange parts
name
Work procedure Remarks
Motorized
control valve coil
Recess
Pulse motor valve body
Positioning
projection
Outlet cabine
t
Bellmouth
Hooks
Fan guard
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 153 Monday, October 5, 2009 2:09 PM