4 Electric parts
replacement
2.Reactor
1)Perform the step 1-1.
2)Remove the reactor lead connected to the control
board.
CN05 White, CN06 White
3)Cut the binding tie that binds the compressor leads
and fan motor leads.
4)Remove the reactor.
(Truss B tight screw Ø4 × 6, 2 screw)
5)Attach a new reactor.
Note)
Be sure to bind the removed binding tie by using
the commercially available binding tie.
Make sure that the fan motor lead and the reactor
body do not contact each other.