Toshiba 9000 Air Conditioner User Manual


 
1. Remove two mask seals at the bottom corners of the
display assembly using a pair of fine-tipped tweezers.
2. Remove two M2.5x6 flat head brass screws securing
the display mask.
3. There are 23 latches securing the display mask.
Carefully insert your fingers between the mask and the
LCD panel and pry open the latches starting from the
six top latches, to the five latches on each right
and left sides, ending with the bottom seven latches.
FL INVERTER AND 14.1” LCD REMOVAL
1. Remove one M2x2.8 silver screw securing the
FL inverter board.
2. Carefully lift up the FL inverter board and
disconnect the LCD/FL cable from CN1 and the
FL cable from CN2.
3. Remove four mask seals to expose four screws
securing the LCD module assembly.
4. Remove four M2X2.8 brass screws securing the
LCD module assembly.
5. Carefully rotate out the top of the LCD module
enough to access the display cable
6. Peel off the tape securing the LCD/FL cable and
disconnect the cable.
7. Remove four M2x2.8 silver screws securing the
right and left LCD brackets.
14.1” DISPLAY MASK REMOVAL
TOSHIBA
Tough Enough for Today’s World.
FIELD REPLACEABLE UNIT DOCUMENTATION
Tecra
TM
9000 Series
Latch
Mask seals
Display
mask
LCD
LCD/
FL cable
LCD module
FL inverter board
M2x4
brass
screws
M2x4
brass
screws
Mask
seals
Mask
seals
FL cable
M2x3 silver screw
Download service manual and resetter printer at http://printer1.blogspot.com