A 0.75 Amp fuse protects the controller from damage due
to power surges and excessive current draw through the
Station Modules. Before replacing the fuse, check for the
probable cause, such as a shorted or improperly connect-
ed control valve wire, then replace the fuse as follows:
1. Unplug the transformer from the wall receptacle.
2. Remove the lower front cover from the controller
housing by sliding it downward.
3. Carefully remove the blown fuse from the retaining
clip.
4. Remove the replacement fuse from the back side of
lower cover and install it into fuse retaining clip.
CAUTION: For continued protection against risk
of fire, replace only with the same type and rat-
ing of fuse.
5. Install the lower front cover.
6. Plug the transformer into the wall receptacle.
1. Turn the control dial to the
OFF position.
2. Remove the lower front cover from the controller
housing by sliding it downward.
3. Place the back of the station control module (model
number MOD 212-02) squarely between the guides
of the first open expansion slot (from left to right).
Pushing lightly on the bottom of the module, slide it
upward until it locks into position.
4. To connect the valve wires, refer to Connecting The
Valves on page 23.
5. Install the lower front cover.
6. To set the station run time, refer to Setting Station
Run Times on page 21.
7. To test the operation of the new watering station(s),
refer to Manual Operations on pages 27 and 28.
Adding A Station Module
Replacing The Fuse
Service and Specifications
31