Thermo Products CHB1-75N Furnace User Manual


 
All installations and services must be performed by qualified service personnel.
2
CDB1 SERIES
MODEL NO.
CDB1-50
CDB1-75
CDB1-100
CDB1-125
BTU/HR INPUT
50,000
75,000
100,000
125,000
BTU/HR OUTPUT
47,000
70,000
94,000
116,000
HT. OF CASING
46-1/4”
46-1/4”
46-1/4”
46-1/4”
WIDTH OF CASING
17”
17”
21”
24”
DEPTH OF CASING
27-1/2”
27-1/2”
27-1/2”
27-1/2”
WARM AIR OUTLET
15 x 18
15 x 18
19 x 18
22 x 18
RETURN AIR INLET
15 x 22
15 x 22
19 x 22
22 x 22
DIA. OF FLUE
2”
2”
3”
3”
DIA. OF COMBUSTION
AIR INTAKE
2” 2” 3” 3”
CFM @ .2” & .5” w.c.
EXTERNAL STATIC PRESSURE
.2” .5” .2” .5” .2” .5” .2” .5”
@HI SPEED
1120 930
1530 1340
1830 1590
2280 2010
@MH SPEED
1000 750
1270 1110
1660 1460
1830 1650
@ML SPEED
-- --
1050 930
1520 1340
1750 1570
@LO SPEED
616 420
850 720
1370 1230
1660 1530
TEMPERATURE RISE
70
70
70
70
BLOWER MOTOR HP
.20
.41
.50
.75
NO. OF SPEEDS
3
4
4
4
RUN CAPACITOR
10 mfd
10 mfd
10 mfd
15 mfd
LARGEST RECOMMEDED
AIR CONDITIONER
2 Ton 3.5 Ton 4 Ton 5 Ton
SIZE OF FILTERS
21-3/4” x 14”(2)
21-3/4” x 14”(2)
21-3/4” x 14”(2)
21-3/4” x 14”(2)
NOTES:
1. BTU output based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is
required.
4. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps. for all models).
5. All specifications are subject to change without notice.