Thermo Products CBD1-125N Furnace User Manual


 
All installations and services must be performed by qualified service personnel.
8
Figure 1
The horizontal furnace installation should be on a service platform large enough to allow for proper clearances on all
sides and service access to the front of the furnace (See Table 1). If the furnace is suspended, it must be supported at
both ends and in the middle with clearance allowed for removal of both access doors. Gas supply line contact is only
permissible between lines
formed by the intersection of the top and two sides of the furnaces casing and the building
joists, studs, or framing (See Figure 1).
Equipment must be installed in accordance with regulations of the National Board of Fire Underwriters and
the National Fuel Gas Code. Authorities having jurisdiction should be consulted before installations are
made.
C. Replacing An Existing Furnace From A Common Vent
: These furnaces may NOT be common vented with any other appliance.