Assembling the Logs
WARNING: DO NOT ADD EXTRA LOGS
OR ORNAMENTS SUCH AS PINE CONES,
VERMICULITE OR ROCK WOOL. USING
THESE ADDED ITEMS CAN CAUSE
SOOTING.
Figure 15
Step 9. The heater includes a set of ceramic
fiber logs. The logs are assembled as shown in
Figure 15
. Handle these logs with great care.
The logs can be easily damaged, but when
handled properly they can provide years of
performance and enjoyment.
Carefully position and center the larger bottom
fiber logs onto the burner.
Place the large center fiber log segment #3
between the two (2) lower logs #'s1 and 2 in the
manner illustrated (
Figures 15 & 16A
). The
flames should not impinge on the logs.
Position the rockwool over the burner screen as
shown in
Figure 16B
.
WARNING: DO NOT PLACE ANY LAVA
ROCK ON LOGS OR BURNERS. THIS MAY
CAUSE SOOTING.
#1
Front
(Valve Side)
#2
#3
#4
#5
#7
#6
Charred Area
Far Side
Charred Area
This Side
Figure 14
White
(Supply)
Black
(Supply)
Bipolar
Terminal
Screw
Blower
(Lower)
Outlet
Black
Wire
Mating
Connectors
Red Wire
120 Vac
60 Hz
Blower Wiring Diagram
}
OFF/ON Blower
Wall Switch
To Fuse or
Circuit Breaker
120V
AC
60Hz
Fireplace
Junction Box
Black
White
Receptacle
Ground Wire
Connection
Install the top four twigs beginning with the left
twig #5 first (
Figure 16C
). Shift the lower logs
left or right as necessary to align the position-
ing pins.
Once twig #5 is in position, place the center
twig #4 on the set, again adjusting the lower
logs left or right as necessary to align the
positioning pins.
Position the top twigs #6 and #7 onto the pins
of the center twig #4 and onto the pins of the
burner.