State Industries SBD71 120 Water Heater User Manual


 
SBD TANK TYPE HEATERS
SERVICE HANDBOOK
Technical Training Department
Ashland City, TN ©2003
33
STEP 13 PILOT SPARK TEST
STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly.
Note: The pilot burner mounts on the left side of the main burner.
NEHT FI
The igniter is not sparking: Check for:
A 7/64” spark gap
Spark cable continuity
Ground cable continuity
Sparking is present: Go to step 14.
Power To Module May Be Interrupted To Reset .
Trial for Ignition
90 sec. 5 min. 90 sec. 5 min. 90 sec.
Call for
heat
Sparking No
Sparking
Sparking No
Sparking
Sparking
Continuous
Trial
Sequence