PLUG THE TEMPERATURE AND PRESSURE RELIEF VALVE.
Also, the leakage could be due to unusually high water
pressures or temperatures in the system, or to a faulty relief
valve. Your dealer or a qualified service technician should be
called to determine the cause of the problem and to correct it.
4. If you cannot identify or correct the source of water leakage:
Close the main shutoff valve in the gas supply pipe at the
heater, see Figure 4, page 7.
Close the valve which feeds water to the cold water inlet at
the top of the heater.
Contact your dealer.
WATER HEATER MAKES SOUNDS
1. Occasional excessive condensation, as explained under
LEAKAGE, can cause a sizzling sound as the moisture is
vaporized by the gas flame. This is a normal sound and may
be disregarded.
2. Sediment and water scale accumulations may cause rumbling
noises. See MAINTENANCE or contact your dealer for details
of flushing the heater.
3. If you cannot identify or remedy the condition, contact your
dealer.