SonicWALL NSA 5000 Home Security System User Manual


 
Page 66 Safety and Regulatory Information
Safety and Regulatory Information
Rack Mounting the SonicWALL
The above SonicWALL appliances are designed to be mounted in a
standard 19-inch rack mount cabinet. The following conditions are
required for proper installation:
Use the mounting hardware recommended by the rack manu-
facturer and ensure that the rack is adequate for the applica-
tion.
Four mounting screws, compatible with the rack design, must
be used and hand tightened to ensure secure installation.
Choose a mounting location where all four mounting holes line
up with those of the mounting bars of the 19-inch rack mount
cabinet.
Mount in a location away from direct sunlight and sources of
heat. A maximum ambient temperature of 104º F (40º C) is
recommended.
Route cables away from power lines, fluorescent lighting fix-
tures, and sources of noise such as radios, transmitters and
broadband amplifiers.
The included power cord is intended for use in North America
only. For European Union (EU) customers, a power cord is not
included.
Ensure that no water or excessive moisture can enter the unit.
Allow unrestricted airflow around the unit and through the
vents on the side of the unit. A minimum of 1 inch (25.44mm)
clearance is recommended.
Mount the SonicWALL appliances evenly in the rack in order
to prevent a hazardous condition caused by uneven mechan-
ical loading.
Consideration must be given to the connection of the equip-
ment to the supply circuit. The effect of overloading the circuits
has minimal impact on overcurrent protection and supply wir-
ing. Appropriate consideration of equipment nameplate rat-
ings must be used when addressing this concern.
Reliable grounding of rack-mounted equipment must be main-
tained. Particular attention must be given to power supply
connections other than direct connections to the branch cir-
cuits such as power strips.
Lithium Battery Warning
The Lithium Battery used in the SonicWALL Internet security appliance
may not be replaced by the user. The SonicWALL must be returned to a
SonicWALL authorized service center for replacement with the same or
equivalent type recommended by the manufacturer. If, for any reason,
the battery or SonicWALL Internet security appliance must be disposed
of, do so following the battery manufacturer's instructions.
Cable Connections
All Ethernet and RS232 (Console) cables are designed for intra-building
connection to other equipment. Do not connect these ports directly to
communication wiring or other wiring that exits the building where the
SonicWALL is located.
Regulatory Model/Type Product Name
1RK13-051
1RK13-051
1RK13-052
NSA 5000
NSA 4500
NSA 3500