Security Centres 808 Home Security System User Manual


 
20 of 22 496336 Issue 1
you have removed power from the end station while in programming mode
with a configuration error.)
The end station will not let you leave programming mode until you have cured
a configuration error.
Note: In a configuration checking error message the display always shows
the words "CFG ERR" alternating with one of the following messages:
A IN LC
Meaning: Area Has No Zones. In the example shown, Level C lists an Area
which has not been assigned any zones.
Action: Check Menus 32 and 41.
LEVELSET O/P 12
Meaning: Levelset Output Will Not Work. In the example shown, output 12 is
a levelset output, but its assignment means that it will never work.
Action: Check Menu 51.
ARMING STN 2
Meaning: Too Many Levels Assigned to Arming Station. In the example
shown Keypad 2 is an arming station. You can only assign one
Level to an arming station.
Action: Check Menu 47.
NON KEY Z IN LA
Meaning: No Keyswitch Zone In Level. In the example shown Level A has
been assigned a keyswitch zone which is not a keyswitch zone
type.
Action: Check Menu 41 or 32.
KEYSWITCH ZONES
Meaning: Keyswitch Zone Assigned to Different Levels. In the example
shown a keyswitch zone has been assigned to more than one Level
in the same Partition.
Action: Check Menu 41.
User Facilities
In User Mode the 808 can store unique access codes for up to eight users.
Each user can be linked to one or more Levels. There are two types of user:
The Supervisor (User 01), who can change all other user's access
to the system.
Ordinary users, who cannot change their level of access to user
functions.
User Facilities 808