Security Centres 808 Home Security System User Manual


 
496336 Issue 1 19 of 22
Menu 50: Program outputs
Menu 51: Output Types = Bell = Normally On, Strobe = Normally
Off, All other NO Function
Menu 52: Internal sounder = Follows Bell
Menu 53: Bell Delay = 0, Bell Time = 20 Minutes
Menu 60: Program System Options
Menu 61: Installer information = Code = 7890
Menu 62: PA response = Audible
Menu 63: Line Fault response = Audible
Menu 64: Allow Zone omits = Disabled
Menu 65: System reset = Customer
Menu 66: Logging Printer = Disabled
Menu 67: First Circuit = Re-arm,
Alarm Abort = Disabled
Entry Abort = Disabled,
Tampers Comms = Disabled, Set
Set No AC (Mains) = Disabled, Reset No AC (Mains) =
Disabled
Alarm Confirmation = Disabled
Fault Finding
General Faults
No response from the keypad keys
Check the keypad wiring.
Check the keypad address programming.
Enter and leave programming mode.
Power up while shorting RST pins.
No exit/entry tones from remote keypad
Check keypad address programming option. (See "Keypads".)
Check keypad is assigned to the Level being set (Menu 47).
Check if keypad faulty.
Configuration Checking Error Messages
The end station checks the configuration when you exit programming mode
or when you apply power. If the end station finds a configuration error during
power up it displays the message "CONFIG ERROR" at the keypad. The
panel is unusable until you cure the problem. (Note that this will only occur if
808 Fault Finding