Power:
Operation voltage
--
12-24 Volts AC/DC. No jumper needed to set voltage.
Stand-by current drain
--
15mA @12VDC.
Active current drain (press keypad key)
--
Under 45mA@12VDC.
Active current drain (one relay activated)
--
Under 80mA@12VDC.
Active current drain (two relays activated)
--
Under 130mA@12VDC.
Outputs:
Relay output #1
--
5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed
output or shunt (start/stop) output. Three terminals.
Relay output #2
--
1A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second momentary
output or shunt (start/stop) output. Three terminals.
Tamper output
--
50mA @ 12VDC, N.C. output. Connect to tamper circuit of alarm control panel.
Two terminals.
Keypad active or alarm output
--
Transistor ground max. 100mA @ 24VDC. Switches to ground (-) for 10
sec. when a key is pressed (keypad active output), or switches to ground (-) to indicate a door was forced
open or propped open (alarm output). Single terminal.
Mantrap (interlock) control output
--
Outputs ground (-) for five seconds after relay output #1 is activated,
continues while the door is open. Use to disable a second keypad during this time. Single terminal.
Ground output
--
Steady ground (-), 100mA @ 24VDC. Single terminal.
Duress output
--
Transistor ground (-), 100mA @ 24VDC. If switches to ground (-) after the duress code
is entered. Single terminal.
Inputs:
Power
--
12-24Volts AC/DC. Two terminals.
Egress
--
N.O., ground (-). Single terminal.
Door sensor input
--
N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or
closed, or connect to ground (-) if not used. Single terminal.
Relay output #1 disable input
--
Connect to ground (-) to prevent relay output #1 from operating, or to the
mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.
Single terminal.
Code Operation:
Auto or manual code entry. Up to 100 user codes for relay output #1, up to 10 user codes for relay
output #2. 111,110,000 possible user code combinations.
Auto refresh time during code entry:
Max. 10 seconds to enter each digit.
Max. 30 seconds to enter each code.
Dimensions (keypad with back box):
4-15/16" x 3-1/8" x 2" (125 x 78 x 51 mm).
Weight
18 oz. (510 grams).
SPECIFICATIONS
1. Master Code: The SK-1123-SQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or
data should be programmed at the owner's discretion. However, to ensure security, program a new personal Master
Code to replace the factory-set Master Code as soon as possible.
2. Factory defaults:
PROGRAMMING NOTES
STATUS
1. In programming mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated
BUZZER TONES*
- - -
1 beep
2 beeps
5 beeps
Continuous beeps
- - -
1-sec. long beep**
AMBER LED FLASHES
ON
1 flash
2 flashes
5 flashes
Continuous flashes
1 flash in 2-sec. intervals
- - -
NOTE: *The buzzer can be disabled through programming option 83, ref. pg. 14.
**The output relay activated beep can be disabled through programming option 81, ref. pg. 14.
BUZZER AND LED SIGNALS
The keypad's built-in buzzer and the amber LED can signal the following:
Door forced open alarm disabled
Output activation announcer ON
User code entry mode manual
Keypress beep ON
Door propped open alarm OFF
Silent operation OFF
LED INDICATORS
Red LED -- Lights while output #2 is activated.
Amber LED -- Flashes to show the keypad status (see below).
Green LED -- Lights while output #1 is activated.
4. Using Duress Codes (Relay #1 only): Duress codes are used to activate a separate device silently to alert a guard
or other personnel that a user is operating the keypad under threat. The keypad operates as normal, but a signal is
sent to alert others.
Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by
increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code.
For example:
User code 4468 can be entered as duress code 6468
User code 9843 can be entered as duress code 1843
User code 8181 can be entered as duress code 0181
NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user
code. For example:
If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot
be programmed.
3. Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the codes have the
same number of digits, the keypad can be programmed for whether the key must be used or not after entering the
code (see programming, option 82, page 14).
The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer authorized to
enter a protected area, without the need to teach the new code to all the other users.
Relay output #1 allows up to 100 user codes, and relay output #2 allows up to 10 user codes.
Master code 0000
User code length 4-8 digit
Main relay output time 1 second
Auxiliary relay output time 1 second
Wrong code lockout 10 tries / 30 sec.
#
Note: Once activated, the duress output continues until a correct user code is entered.
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
____________________________________________________________________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
Page 12 Page 5